A. Normal Operation Menu:
The
Normal Operation
LCD screen indicates that
the control board has booted successfully (OK); the
pressure reading is 0 psi. The operator can now enter
into the menus by pressing the “Menu” button.
B. Auto Mode Menu:
This screen allows the operator to toggle the tube puller
Auto Cycle mode ON or OFF. With Automode OFF, the
menu Set Pres (Firmware 5.5 and earlier) or HI PRESS
(Firmware 5.6 and later) will not be available and the Set
Press / HI PRESS pressure value has no effect on the
pump. Switch it ON or OFF by pressing either the Down
or Up Arrow buttons.
NOTE: Firmware 5.6 and later - Setting the value to
ON also changes the Normal Operations menu text
message from “OK” to “AUTO”. Save the setting
and step forward by pressing the Menu button.
C. Set Press or High Press Menu
(only available with
Automode ON):
This screen allows the operator to set the Advance
port pressure value the tube puller will Auto Cycle at.
Changes in increments of 50 psi (3.5 bar) by pressing
either the Down or Up Arrow button or keep either button
pressed for speed setting. Maximum pressure value is
10,000 psi (700 bar). Save the setting and step forward
by pressing the Menu button.
NOTE: Firmware 5.5 and earlier: The hidden
calibration menu for the digital gauge is accessed
from this menu.
D. Units Menu:
This screen allows the operator to set the unit of
pressure-measurement by pressing either the Down or
Up Arrow button. The options available are PSI, BAR,
Mpa with PSI being the default. Save the setting and
step forward by pressing the Menu button.
NOTE: Firmware 5.6 and later: The hidden calibration
menu for the digital gauge is accessed from this
menu.
Airetool
®
General Instructions
Figure 14: Normal Operation Menu
Figure 15: Auto Mode Menu
Figure 16: Set Press or HI PRESS Menu
Figure 17: Units Menu