CR12-165 

  

CONDENSERS

 

 

Condenser 

 

13 

                                                                                                        Technical Manual :6666879 1.2.0 08_2014 

/2012  

 

 

Horizontal case size 5 (4 fans) 

 

150

150

(4)

(5a)

(5b)

A

B

D(a)

D(b)

D(c)

(3)

(1)

(1)

E

C

 

For Minimum Clearances (2) see previous outdoor units in horizontal configuration 
 
Diagram illustrated in mm 
 
(1) 

Airflow 

(2) 

Minimum clearances 

(3) 

12.7mm fixing hole 

(4) 

Mains electric isolator 

(5) 

Service connections to left hand side of the unit: 
a = Discharge gas inlet (ALWAYS above (b)) 

 

b = Liquid outlet 

(6) 

Top brackets may be used to secure unit of similar size on top, using, 2 x 12.7mm fixing holes 

(7) 

40mm lifting holes 

 

 

DIMENSIONS (mm) 

WEIGHTS (kg) 

 

Standard Fan 

Standard 

AC Fan 

Optional 

EC Fan 

Optional 

SCAF 

 

D(a) 

D(b) 

D(c) 

CR140 

4641 

1167 

1000 

1524 

1539 

1524 

700 

349 

375 

394 

CR165 

4641 

1167 

1000 

1524 

1539 

1524 

700 

415 

462 

404 

 

CAUTION 

  

 

A vertical air discharge unit is recommended for installation in windy locations or wherever a 
horizontal airflow would be obstructed. 

 

Vertical case size 5 (4 fans) 

B

(5b)

(5a)

(4)

(3)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

3000

(2)

(6)

D(a)

D(b)

D(c)

A

E

C

 

For minimum clearances (2) see previous outdoor units in vertical configuration 
 
Diagram illustrated in mm

 

 
(1) 

Air flow 

(2) 

Minimum clearances 

(3) 

12.7mm fixing hole 

(4) 

Mains electric isolator 

(5) 

Service connections to left hand side of the unit: 

            a = Liquid outlet 
            b = Discharge gas inlet 

(6) 

40mm lifting holes 

(7)        Optional short case axial fan with integral duct fixing holes

 

 

 

DIMENSIONS (mm) 

WEIGHTS (kg) 

 

Standard Fan 

Fan Options 

Standard 

AC Fan 

Optional 

EC Fan 

Optional 

SCAF 

 

SCAF 

EC 

 

D(a) 

D(b) 

D(c) 

 

 

 

CR140 

4641 

1090 

1167 

1524 

1539 

1524 

1107 

1130 

1127 

349 

375 

394 

CR165 

4641 

1155 

1167 

1524 

1539 

1524 

1107 

1140 

1170 

415 

462 

404 

Содержание CR12 - CR165

Страница 1: ...COVER Condenser CR12 CR165 TECHNICAL MANUAL ...

Страница 2: ...h every unit and is also available from our Spares department on request TRAINING As well as our comprehensive range of products Airedale offers a modular range of Refrigeration and Air Conditioning Training courses for further information please contact Airedale CUSTOMER SERVICES For further assistance please e mail enquiries airedale com or telephone Customer Services UK Sales Enquiries 44 0 113...

Страница 3: ...hen a component part fails a replacement part should be obtained through our Spares department If the part is considered to be under warranty the following details are required to process this requirement Full description of part required including Airedale s part number if known The original equipment serial number An appropriate purchase order number A spares order will be raised under our warra...

Страница 4: ...otor 8 Optional Extras General 8 Short Case Axial Fans SCAF 8 Corrosion Resistant Coated Coils 8 Shut Off Valves 8 Coil Guards 8 Installation data 9 Dimensions Weights Positioning 9 Unit Lifting 14 General 14 Horizontal Air Discharge 14 Vertical Air Discharge 14 Performance Data Condensers 15 Standard Condenser Fan 15 CAPACITY DATA 16 Standard Condenser Fan 16 Sound Data 17 Method of Sound Measure...

Страница 5: ... carry a holding charge of inert gas The condenser range has been designed and optimised for operation with ozone benign refrigerant R410A CE Directive Airedale certify that the equipment detailed in this manual conforms with the following EC Directives Electromagnetic Compatibility Directive EMC 2004 108 EC Low Voltage Directive LVD 2006 95 EC Machinery Directive MD 89 392 EEC in the version 2006...

Страница 6: ...d and stored safely if not required IMPORTANT Only 2 units may be stacked together Vertical Air Discharge As standard unit legs shall be attached and delivered in the horizontal air discharge mode and shall be repositioned on site to offer vertical air discharge mode refer to Dimensions Weights Positioning for details IMPORTANT To ensure the unit isolator and fan speed controller are in the correc...

Страница 7: ...lease specify at order Refer to Error Reference source not found for fan options REFRIGERATION Each unit shall feature as standard Holding Charge of inert gas ELECTRICAL All electrical components shall be rated for all year round outdoor use All wiring shall be colour coded and numbered for identification All units shall be wired in accordance with current local and European standards HEAD PRESSUR...

Страница 8: ...C fan control module shall allow for fan speed modulation from 0 100 the modulating range of a standard AC fan is typically 40 100 of full fan speed Optional Extras General SHORT CASE AXIAL FANS SCAF Short case axial fans shall be supplied for indoor installations where discharge air requires to be ducted to an outdoor location The fans shall meet duty plus nominal 75Pa of external static pressure...

Страница 9: ...ng illustrations show the unit following fixing leg re orientation instructions are provided for this at delivery IMPORTANT The legs attached to the top of the unit are for lifting and stacking and may be removed and stored safely if not required Stacking units Only 2 units may be stacked together In addition to the standard minimum clearances around the unit further space is required Positioning ...

Страница 10: ...CR22 1102 1167 1000 1040 700 77 83 88 CR26 1102 1167 1000 1040 700 93 105 90 CR30 1102 1167 1000 1040 700 90 96 101 CR35 1102 1167 1000 1040 700 106 118 103 Vertical case size 1 and 2 1 Fan 3000 2 1 D A B 6 3 1 C E 5b 4 5a 500 2 500 2 500 2 500 2 Diagram illustrated in mm 1 Airflow 2 Minimum clearances 3 12 7mm fixing hole 4 Mains electric isolator 5 Service connections to left hand side of the un...

Страница 11: ...000 2121 700 165 188 159 CR65 2184 1167 1000 2121 700 162 175 184 CR75 2184 1167 1000 2121 700 195 218 189 Vertical case size 3 2 Fans DIMENSIONS mm WEIGHTS kg Standard Fan Fan Options Standard AC Fan Optional EC Fan Optional SCAF SCAF EC A B C D E B B CR50 2184 1090 1167 2124 1107 1130 1127 132 145 154 CR60 2184 1155 1167 2124 1107 1140 1170 165 188 159 CR65 2184 1090 1167 2124 1107 1130 1127 162...

Страница 12: ...167 1000 1752 700 258 293 249 CR105 3565 1167 1000 1752 700 260 280 294 CR130 3565 1140 1167 1752 1107 310 345 301 The SCAF fans in the horizontal mode do not obtrude past the mounting feet Vertical case size 4 3 fans Optional Short Case Axial Fan SCAF 3000 2 C E 5b 4 5a 1 D A B 6 3 1 D 1 1 500 2 500 2 500 2 500 2 7 Diagram illustrated in mm 1 Airflow 2 Minimum clearances 3 12 7mm fixing hole 4 Ma...

Страница 13: ...375 394 CR165 4641 1167 1000 1524 1539 1524 700 415 462 404 CAUTION A vertical air discharge unit is recommended for installation in windy locations or wherever a horizontal airflow would be obstructed Vertical case size 5 4 fans B 5b 5a 4 3 1 1 1 1 1 1 1 1 1 1 1 1 3000 2 6 D a D b D c A E C For minimum clearances 2 see previous outdoor units in vertical configuration Diagram illustrated in mm 1 A...

Страница 14: ...ely HORIZONTAL AIR DISCHARGE The unit is delivered in horizontal air discharge configuration secured to a pallet Where possible the unit should be moved with the pallet in place Use 4 lifting eyes attached to 4 individual slings chains supplied by others and attach 2 to each top leg using the holes provided as illustrated VERTICAL AIR DISCHARGE The unit is delivered in horizontal air discharge con...

Страница 15: ...2 8 24 2 15 7 6 7 50 41 7 33 1 24 6 16 0 7 0 55 51 0 42 3 33 7 25 1 16 4 7 7 CR26 35 19 2 7 8 40 29 9 19 4 8 0 45 40 9 30 3 19 6 8 4 50 52 1 41 4 30 7 20 0 8 8 55 63 5 52 9 42 1 31 4 20 5 9 9 CR30 35 19 8 8 1 40 30 6 20 0 8 4 45 41 7 30 9 20 2 8 7 50 53 1 42 1 31 3 20 5 9 2 55 64 8 53 8 42 8 31 9 21 0 9 8 CR35 35 25 4 10 5 40 39 4 25 7 10 9 45 53 6 39 7 26 0 11 3 50 68 1 54 2 40 3 26 4 11 8 55 83 ...

Страница 16: ...0 148 4 118 1 87 8 57 5 25 8 55 180 9 150 4 120 89 5 58 9 28 3 CR95 35 69 7 29 2 40 108 70 4 30 2 45 147 109 3 71 3 31 4 50 186 7 148 9 110 9 72 6 32 8 55 227 6 189 5 151 4 113 1 74 5 37 CR105 35 72 1 30 40 110 8 72 6 31 45 150 4 111 7 73 3 32 2 50 191 1 152 1 113 2 74 5 33 8 55 233 3 193 8 154 6 115 5 76 3 36 4 CR130 35 95 3 40 5 40 146 3 95 9 41 7 45 198 3 147 6 97 43 2 50 251 6 200 6 149 7 98 6...

Страница 17: ...40 37 32 22 CR16 Power 74 72 83 76 68 68 65 60 50 Pressure 10m 46 44 55 48 40 40 37 32 22 CR22 Power 78 82 87 74 74 73 70 63 62 Pressure 10m 50 54 59 46 46 45 42 35 34 CR26 Power 82 83 80 82 79 78 74 67 59 Pressure 10m 54 55 52 54 51 50 46 39 31 CR30 Power 78 82 87 74 74 73 70 63 62 Pressure 10m 50 54 59 46 46 45 42 35 34 CR35 Power 82 83 80 82 79 78 74 67 59 Pressure 10m 54 55 52 54 51 50 46 39 3...

Страница 18: ...55 52 55 54 51 51 45 40 32 CR50 Power 82 83 93 76 77 77 73 67 66 Pressure 10m 54 55 65 48 49 49 45 39 38 CR60 Power 86 83 86 85 82 82 76 71 63 Pressure 10m 58 55 58 57 54 54 48 43 35 CR65 Power 82 83 93 76 77 77 73 67 66 Pressure 10m 54 55 65 48 49 49 45 39 38 CR75 Power 86 83 86 85 82 82 76 71 63 Pressure 10m 58 55 58 57 54 54 48 43 35 CR80 Power 84 78 93 79 78 80 75 69 68 Pressure 10m 56 50 65 5...

Страница 19: ...nt Type R410A Holding Charge Inert Gas Coil Volume l 3 0 6 0 4 7 4 7 9 3 Refrigerant Charge 3 kg 1 4 2 7 2 2 2 2 4 3 Dry Cooler Internal Water Volume L 6 6 6 6 11 9 Nominal Flowrate l s 0 53 0 65 0 7 Pressure Drop kPa 11 9 17 8 20 7 Connections Liquid Line Sweat in 5 8 5 8 5 8 5 8 3 4 Discharge Line Sweat in 5 8 5 8 5 8 5 8 3 4 OPTIONAL EXTRAS Short Case Axial Fan Designed to 75 Pa ESP Dimensions ...

Страница 20: ...g Charge Inert Gas Coil Volume l 9 3 10 7 10 7 21 4 21 4 Refrigerant Charge 3 kg 4 3 4 9 4 9 9 8 9 8 Dry Cooler Internal Water Volume L 11 9 14 8 14 8 26 7 26 7 Nominal Flowrate l s 0 9 1 2 1 47 1 64 2 1 Pressure Drop kPa 46 4 15 3 20 5 38 5 60 4 Connections Liquid Line Sweat in 3 4 3 4 Discharge Line Sweat in 1 1 8 1 1 8 1 1 8 1 1 8 OPTIONAL EXTRAS Short Case Axial Fan Designed to 75 Pa ESP Dimen...

Страница 21: ... Type R410A Holding Charge Inert Gas Coil Volume l 18 3 18 3 36 6 Refrigerant Charge 3 kg 8 4 8 4 16 7 Dry Cooler Internal Water Volume L 23 1 23 1 43 2 Water flowrate l s 2 0 2 5 2 6 Pressure Drop kPa 48 5 70 32 Connections Liquid Line Sweat in 7 8 7 8 7 8 Discharge Line Sweat in 1 3 8 1 3 8 1 3 8 OPTIONAL EXTRAS Short Case Axial Fan Designed to 75 Pa ESP Dimensions Horizontal H x W x L mm 1167 x...

Страница 22: ...ant Type R410A Holding Charge Inert Gas Coil Volume l 36 6 TBC TBC Refrigerant Charge 3 kg 16 7 TBC TBC Dry Cooler Internal Water Volume L 43 2 55 9 55 9 Water flowrate l s 3 4 3 5 4 6 Pressure Drop kPa 53 62 94 Connections Liquid Line Sweat in 7 8 7 8 7 8 Discharge Line Sweat in 1 3 8 1 3 8 1 3 8 OPTIONAL EXTRAS Short Case Axial Fan Designed to 75 Pa ESP Dimensions Horizontal H x W x L mm 1140 x ...

Страница 23: ... 1 3 3 2 6 3 3 2 6 3 3 2 6 3 3 Condenser CR75 CR80 CR95 CR105 CR130 CR140 CR165 Unit Data 1 Nominal Run Amps A 3 3 7 86 4 95 7 86 4 95 10 48 6 6 Maximum Start Amps A 12 2 27 5 18 3 27 5 18 3 36 7 24 4 Recommended Mains Fuse A 6 16 10 16 10 16 10 Max Mains Cable Incoming mm 6 6 6 6 6 6 6 Mains Supply 50Hz 400V 3Ph 230V 1Ph 400V 3Ph 230V 1Ph 400V 3Ph 230V 1Ph 400V 3Ph Fan Per Fan Quantity 2 3 3 3 3 ...

Страница 24: ...CR12 165 CONDENSERS 24 24 Condensers Technical Manual 6666879 1 2 0 08_ 2014 NOTES NOTES ...

Страница 25: ...CR12 165 CONDENSERS Condenser 25 Technical Manual 6666879 1 2 0 08_2014 2012 ...

Страница 26: ...International Air Conditioning Ltd Leeds Road Rawdon Leeds LS19 6JY United Kingdom Tel 44 0 113 239 1000 Fax 44 0 113 250 7219 e mail enquiries airedale com website www airedale com PART NO ISSUE TM E 10 2012 1 1 0 02_2013 ...

Отзывы: