![Aircel CDP Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/aircel/cdp-series/cdp-series_installation-and-operation-manual_2876264011.webp)
11
Heatless Regenerative Air Dryer
Diagram 1: How it Works
Drying
Tower
Regenerating
Tower
Air Saturated with Moisture
Dry Air
F1
F2
T2
T1
V1
V2
F1 - Mounted Pre-Filter
F2 - Mounted After-Filter
V1 - Automatic Piston Valve
V2 - Automatic Piston Valve
V3 - Purge Exhaust Valve
V4 - Purge Exhaust Valve
T1 - Desiccant Tower 1
T2 - Desiccant Tower 2
V4
V3
Regeneration Air