15
deactivation, by up to sixty seconds. These delays can prove useful in
moderating alarm responses to weight oscillations, such as those
occurring during travel. For details, see Product Application Note
Installing and Programming Overweight Alarms, P/N 903-0122-000.
To deactivate and reset an active
warning
or
alarm weight
alarm, simply
press the Enter button <ENTER> once while one of the weight displays
for tractor, trailer or GVW/NET screen is displayed on the scale display
screen.
If the scale is not PIN-protected
, this will stop power from flowing
to the alarm output wire. Once the displayed weight readings fall below
the programmed alarm settings, the alarm function resets. The alarm
feature is now ready for the next load.
IV.D.1. Alarm Function Programming Procedure
IV.D.1.a. ALARM WEIGHTS
1. Press <ESC> one or more times until the Main Menu appears, with
VIEW WEIGHTS blinking.
2. Select ALARMS, leading to the next menu.
If PIN is needed for access, enter it at this time.
(See Section IV.C for PIN setup instructions)
3. Select SET ALARMS, leading to the next menu.
4. Select ALARM 1, leading to the next menu.
5. Select one of GVW, NET ALM 1, TRCTR ALRMS1, or TRLER
ALRMS1, leading to the next menu.
6. Depending on the previous step,
select from GVW ALARM and NET ALARM;
or from STEER ALARM and DRIVE ALARM;
or from TRLR WARN 1 and TRLR ALARM 1. (If there are
multiple trailers, it will be necessary to select from TRAILER A,
TRAILER B, TRAILER C, etc.)
7. Select WARN WT 1 or ALARM WT 1 for the chosen alarm.
8. Using the up/down arrows <
> scroll to the desired warning or
alarm weight, then depress <ENTER>.
9. Press <ESC> as needed to start setting any additional desired
alarms. Press <ESC> repeatedly to return to previous menu or the
main menu. Repeat this procedure for ALARM 2 if used.
IV.D.1.b. TURNING THE ALARM FEATURE ON OR OFF
1. Press <ESC> one or more times until the Main Menu appears, with
VIEW WEIGHTS blinking.
2. Select ALARMS, leading to the next menu.
If PIN is needed for access, enter it at this time.
Содержание LoadMax
Страница 31: ...31 Notes...