14
Note: You can turn off the How-To-Weigh instructions temporarily,
until the next time you turn the truck off and on, by pushing either of
the up/down arrows <
> when the instructions are visible
.
IV.C. Creating a PIN
When the trailer scale PIN is set to 0, the operator will not need to enter a
PIN to access the PROGRAM menu functions. Setting a PIN into the
LoadMaxx Tra
ctor Scale will eliminate tampering with that scale’s
CALIBRATION, SCALE TYPE, and PIN settings. After calibration, fleets
with both tractor and trailer scales should develop a fleet PIN policy to
protect the calibration settings
from tampering.
To set a PIN:
1. Select PRINT,SETUP, leading to the next menu.
2. Select SYSTEM SETUP, leading to the next menu.
3. Select SYS CONFIG, leading to the next menu.
4. Select SET PIN #, leading to the next menu.
If PIN is needed for access, enter it at this time.
5. Using the up/down arrows <
> scroll to the desired PIN, then
depress <ENTER>. Press <ESC> repeatedly to return to main
menu.
The new PIN is now entered into the scale. To change the PIN later,
repeat these steps and change the setting. Setting the PIN to zero will
reset the scale
’s PIN to its original status of No PIN Needed.
Note that once you gain PIN access by entering the PIN correctly, you will
retain that access until the scale has a power cycle.
IV.D. Alarm Function
The Air-Weigh LoadMaxx Tractor Scale has two 12V-24V 1.0 amp output
alarms. To use the alarm feature, attach the gray or brown alarm output
wire stemming from the Tractor ComLink harness to a user-supplied
alarm. Wires are marked WARN 1 and WARN 2. Route the ground wire/s
for the alarm/s to the WARN GROUND wire/s at the Tractor ComLink
harness. Alarms will activate when a programmed
warning weight
or
alarm weight
limit is reached. The limits activating this feature are set by
the user. The user may also select Alarm 2 to activate when the STEER
weight is less than 20% of the GVW.
Warning weight
output is pulsing voltage, while
alarm weight
output is
continuous voltage.
You can delay the period between each overweight and the subsequent
activation of the alarm, by up to sixty seconds. Similarly, you can delay
the period between the return to not overweight, and the alarm’s