![Air Oasis NANO INDUCT Sanifier Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/air-oasis/nano-induct-sanifier/nano-induct-sanifier_owners-manual_2875418004.webp)
Status Indicator Lights
Power Adapter
The Status Indicator Lights are located on the side of the Ballast Assembly. The in-
dicator lights will provide you with important information about the operating status
of your unit. They will provide you with the following information:
“Lamp Status” Indicator
Green
Unit has power, ballast and UVC lamp are operating
correctly.
Red
Unit has power, UVC lamp is defective or not prop-
erly connected.
“Lamp Replacement” Indicator
Blue Solid
The UVC lamp is within its two year life span. No
action is needed.
Blue Flashing
The UVC lamp is outside its two year life span, output
has decreased and it should be replaced.
No Lights Illuminated
There are two possibilities.
1. The unit is not properly connected to the power
supply.
2. The ballast exceeded the safe operating tem-
perature. The thermal protector opened the
circuit disconnecting power to the ballast. The
circuit will automatically reset when the ballast
cools.
Status Indicator Lights
The nano Induct is powered using a 26 VDC power adapter with a rated input volt-
age of 100 - 240 VAC. The adapter connects to a 110 or 230 VAC 3 amp power
cord. For your safety and to ensure proper function of your nano Induct we recom-
mend that ONLY the power adapter included with the original purchase be used.
2
Placement and Installation