Air Oasis NANO INDUCT Sanifier Скачать руководство пользователя страница 12

Troubleshooting Guide

nano Induct Specifications

Problem/Question

Solution/Answer

What if my NIND won’t turn 

on? The indicator lights  are 

not illuminated.

Check to make sure the power adapter is firmly plugged 

into the electrical outlet and the NIND. 

The Lamp Status indicator 

light has turned from green 

to red.

Reset  the  unit  by  unplugging  it  for  the  power  source. 
Check to make sure the four pins on the AHPCO

®

 Cell 

are fully inserted into the Ballast Assembly. Reconnect the 

power. If the indicator light is still red contact Air Oasis or 

an authorized dealer. 

The Lamp Replacement indi-

cator light is blinking.

This is an indication that it has been two years since the 
AHPCO

®

  Cell  has  been  replaced.  Contact  an Air  Oasis 

authorized dealer to purchase a new AHPCO

®

 Cell.

If the above does not repair the symptom please contact an Air Oasis Customer Service 

Representative:

Phone: 1-800-936-1764

E-mail: [email protected]  Web: www.airoasis.com
Mail: Air Oasis

Customer Service

3401 Airway Blvd..

Amarillo, TX 79118

Operational

NIND6 Coverage

NIND9 Coverage

NIND14 Coverage

Warranty

Up to 3 tons (1200 CFM)

Up to 4 to 6 tons (1600 - 2400 CFM)

Up to 7+ tons (4800+ CFM)

Two year limited warranty

Replacements

NINDAHPCO 6, 9, or 14

Replace every two years.

Electrical

NIND6 Usage

NIND9 Usage

NIND14 Usage

24 VAC/26VDC, 0.40 Amps, 11 Watts

24 VAC/26VDC, 0.50 Amps, 13 Watts

24 VAC/26VDC, 0.68 Amps, 18 Watts

Mechanical

NIND6 Dimensions

Weight of Unit

Shipping Weight

NIND9 Dimensions

Weight of Unit

Shipping Weight

NIND14 Dimensions

Weight of Unit

Shipping Weight

4” L x 4” W x 8.1” H

1 lbs

4 lbs

4” L x 4” W x 10.7” H

1 lbs

5 lbs

4” L x 4” W x 15.8” H

1.4 lbs

5 lbs

Copyright© 2015 Air Oasis LLP. All Rights Reserved.

Содержание NANO INDUCT Sanifier

Страница 1: ...For use with models NIND14 NIND9 NIND6 For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit NANO INDUCT Owner s Manual...

Страница 2: ...ensure you get the most benefits from your Sanifier For additional information please contact us mail Air Oasis LLP Attn Customer Service 3401 Airway Blvd Amarillo TX 79118 web www airoasis com e mail...

Страница 3: ...port 4 F 180 F humidity 10 90 Non Condensing Do not operate unit in ambient temperatures above 150 F KEEP OUT OF REACH OF CHILDREN Only use the power adapters included with the purification system WAR...

Страница 4: ...Flashing The UVC lamp is outside its two year life span output has decreased and it should be replaced No Lights Illuminated There are two possibilities 1 The unit is not properly connected to the po...

Страница 5: ...in the closed position The shields should only be opened for specialized applications The nano Induct should not be installed in extremely close proximity to heat strips or other heat sources Polymer...

Страница 6: ...injury to yourself or others if you elect to install the device without utilizing qualified technicians Use the suggestions on page 3 to determine the optimal mounting location s To complete the insta...

Страница 7: ...help secure the unit 5 Firmly press the Ballast Assembly onto the four pins protruding from the AHPCO Cell The Ballast Assembly should be orientated with the air flow label running parallel with the l...

Страница 8: ...warning labels in close proximity to the NIND device 6 CAUTION DONOTLOOK ATUVLIGHT CAUTION WARNING Eye damage may result from directly viewing the light produced by these lamps To reduce the risk of e...

Страница 9: ...tion and servicing of air conditioning equipment can be hazardous due to system pressure and electrical components Only trained and qualified service personnel should install repair or service air con...

Страница 10: ...ll and pull the AHPCO Cell out from the Re tainer Ring Properly dispose of the AHPCO Cell 4 Insert the new AHPCO Cell and secure with four 1 4 hex head screws Do not overtighten the screws 5 Using a s...

Страница 11: ...rranty Card If you purchase this product from any source other than Air Oasis or an Air Oasis dealer your purchase is AS IS which means Air Oasis grants you no warranty and that you not Air Oasis assu...

Страница 12: ...purchase a new AHPCO Cell If the above does not repair the symptom please contact an Air Oasis Customer Service Representative Phone 1 800 936 1764 E mail feedback airoasis com Web www airoasis com M...

Отзывы: