Air King D4S Скачать руководство пользователя страница 7

INSTRUCTIONS IMPORTANTES – 

MODE D’EMPLOI

CONSERVER CES INSTRUCTIONS

www.airkinglimited.com

6727900 Rev. D 9-16

7 of 12

Ventilateur d’Évacuation

Modèles: D4S, D4SG, D4SH, D4SGH

LIRE ET CONSERVER CES INSTRUCTIONS

LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE 

RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT 

TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT 

RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À LA PROPRIÉTÉ.

CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCES FUTURES.

INSTRUCTIONS GÉNÉRALES DE SÉCURITÉ

Lors de l’utilisation d’appareils électriques, des précautions 

de base doivent toujours être suivies pour réduire les risques 

d’incendie, de choc électrique et de blessures corporelles, incluant ce qui suit:

AVERTISSEMENT :

 POUR RÉDUIRE 

LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE 

OU DE BLESSURES PERSONNELLES OBSERVER CE QUI SUIT: 

a)  Utiliser cette unité seulement de la manière pour laquelle le fabricant l’a 

conçu. Si vous aviez des questions, veuillez contacter le fabricant.

b)  Avant d’effectuer un service ou de nettoyer l’unité, couper 

l’alimentation électrique dans le panneau de distribution et verrouiller 

le dispositif de déconnexion afin d’éviter que l’alimentation ne 

revienne accidentellement. Lorsque le dispositif ne peut être 

verrouillé, fixer solidement un avis d’avertissement, tel qu’une 

étiquette, au panneau de distribution.

AVERTISSEMENT :

 POUR RÉDUIRE 

LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE 

OU DE BLESSURES PERSONNELLES OBSERVER CE QUI SUIT: 

a)  Le travail d’installation et le câblage électrique doivent être effectués par 

une(des) personne(s) qualifiée(s) en conformité avec tous les codes et 

normes applicables, incluant la construction relative aux incendies.

b)  De l’air en quantité suffisante est requis pour la bonne combustion 

et l’évacuation de gaz par le conduit (cheminée) provenant d’équipement 

de brûlage au combustible pour prévenir un 

refoulement. Suivre les directives du fabricant de l’équipement de 

chauffage et les normes de sécurité telles que celles publiées par la 

National Fire Protection Association (NFPA) et de la American Society for 

Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), et de 

celles des autorités locales du code.

c)  Lors de coupe ou de perçage des murs et plafonds, ne pas 

endommager le filage électrique et autres utilités cachées.

ATTENTION :

 

POUR USAGE DE VENTILATION 

GÉNÉRALE EXCLUSIVEMENT. NE PAS UTILISER POUR 

ÉVACUER DU MATÉRIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES.

d)  Les ventilateurs avec conduits doivent toujours être évacués vers 

l’extérieur

e)  Si cet appareil doit être installé au-dessus d’une baignoire ou d’une 

douche, il doit être marqué comme approprié pour l’application et 

connecté à un DDFT (disjoncteur différentiel de fuite à la terre) - circuit 

de dérivation protégé. 

f)  Cette unité doit être mise à la terre
g)  Pour éviter des dommages aux roulements des moteurs et/ou des 

hélices bruyantes ou déséquilibrées, empêcher la poussière de cloison 

sèche, poussière de construction, etc., d’atteindre l’unité de puissance.

h)  Lire toutes les instructions avant d’installer ou d’utiliser la ventilateur.

AVERTISSEMENT :

 POUR RÉDUIRE 

LES RISQUES D’INCENDIE OU DE CHOC 

ÉLECTRIQUE, NE PAS UTILISER CE VENTILATEUR AVEC UN RÉGULATEUR 

DE VITESSE ÉLECTRONIQUE.

AVERTISSEMENT :

 NE PAS UTILISER DANS LES 

CUISINES

AVERTISSEMENT : 

LA CANALISATION DE CE 

VENTILATEUR À L’EXTÉRIEUR DU BÂTIMENT A UN EFFET 

IMPORTANT SUR LE FLUX D’AIR, LE BRUIT ET LA CONSOMMATION 

D’ÉNERGIE DU VENTILATEUR. UTILISEZ LA ROUTE DE CANALISATION 

LA PLUS COURTE ET LA PLUS DROITE POSSIBLE POUR UNE MEILLEURE 

PERFORMANCE, ET ÉVITEZ D’INSTALLER LE VENTILATEUR AVEC 

DES CONDUITS PLUS PETITS QUE RECOMMANDÉ. L’ISOLATION 

AUTOUR DES CONDUITS PEUT RÉDUIRE LA PERTE D’ÉNERGIE ET 

EMPÊCHER LE DÉVELOPPEMENT DE MOISISSURES. IL SE PEUT QUE 

LES VENTILATEURS INSTALLÉS AVEC DES CONDUITS EXISTANTS 

N’ATTEIGNENT PAS LEUR DÉBIT D’AIR NOMINAL.

Содержание D4S

Страница 1: ...ent air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Страница 2: ...the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727900 Rev D 9 16 2 of 12 SECTION 4 Ducting NOTE 6 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong ...

Страница 3: ... to the green wire from the fan housing Figure 9 Use approved methods for all connections NOTE The yellow wire may contain a wire crimp nut which will have to be cut off and the wire stripped 4 Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier SECTION 6 Completing the Installation 1 Use a sealant appropriate for con...

Страница 4: ...nimum on time to 30 minutes see numbers in Step 2b The sensor will then flash the number of times for the new setting 3 times before exiting back to the programming mode 3 Once all setting have been made and the sensor will return to detection mode and the LED will flash when occupancy of the room is detected SECTION 8 Setting the Humidistat This fan may be equipped with a humidity sensor that aut...

Страница 5: ... does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIE...

Страница 6: ...acement Part 7 1 Grill 5S1202048 8 1 Wire Compartment Assembly 5S1250103 Specific to Model D4SG Qty Description Replacement Part 9 1 Wire Compartment Assembly 5S1250114 15 1 Grill Assembly 5S1239115 Specific to Model D4SH Qty Description Replacement Part 7 1 Grill 5S1202048 10 1 Wire Compartment Assembly 5S1250115 13 1 Knob 5S1299802 14 1 Humidity Sensor Compartment 5S1239826 Specific to Models D4...

Страница 7: ...uit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorités locales du code c Lors de ...

Страница 8: ...es rails aux solives Figure 1 www airkinglimited com 6727900 Rev D 9 16 8 of 12 SECTION 4 Conduits NOTE UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX REMARQUE La canalisation de ce ventilateur à l extérieur du bâtiment a un effet important sur le flux d air le bruit e...

Страница 9: ...ectez le fil de la position automatique sur l interrupteur mural au fil noir du ventilateur connectez le fil de la position manuelle sur l interrupteur au fil jaune du ventilateur Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur Figure 9 Utiliser des méthodes approuvées pour toutes les connexions REMARQUE Le fil jaune peut contenir un écrou de fil à sertir qui devra êtr...

Страница 10: ...de mouvement sur le gril du ventilateur et appuyez sur le bouton 10 fois Le LED sur le capteur clignote alors le nombre de fois pour indiquer le réglage actuel Ceci sera répété 3 fois 1 fois 0 minutes 4 fois 45 minutes 2 fois 15 minutes 5 fois 60 minutes 3 fois 30 minutes 2c Pour ajuster le réglage tandis que le capteur est continue de clignoter de l étape 2b appuyez sur le bouton le nombre de foi...

Страница 11: ...te garantie ne couvre pas les coûts d expédition pour le retour des produits à Air King pour la réparation ou le remplacement Air King payera les frais d expédition de retour de Air King après les réparations ou le remplacement de garantie TOUTES LES GARANTIES EXPRESSES OU TACITES COMPRENANT SANS LIMITATION TOUTE GARANTIE TACITE DE VALEUR MARCHANDE DURENT UN AN DE LA DATE DE L ACHAT ORIGINAL OU JU...

Страница 12: ... 5S1202048 8 1 Assemblée du compartiment du fil 5S1250103 Particularités de modèle D4SG Qté Description de pièce de remplacement 9 1 Assemblée du compartiment du fil 5S1250114 15 1 Assemblée de Grille 5S1239115 Particularités de modèle D4SH Qté Description de pièce de remplacement 7 1 Grille 5S1202048 10 1 Assemblée du compartiment du fil 5S1250115 13 1 Bouton 5S1299802 14 1 Compartiment du capteu...

Отзывы: