1b.  Internal Wire Compartment: If the motor is already installed in the housing, remove the 

two screws holding the blower assembly in place. Lift up on the assembly and slide it 

out of the tabs on the housing 

(Figure 6)

. Remove the wire compartment cover screw 

and place the cover in a secure place 

(Figure 7).

NOTE:

 If the fan motor plug is connected to the fan housing receptacle, unplug so the blower 

assembly can be completely removed.

Standard and Motion Sensing Models

2a.  Run wiring from an approved wall switch (not included) carrying the appropriate 

rating. One neutral (white), one ground (green or bare copper), and one hot (black lead 

connected to the switch). Secure the electrical wires to the housing with an approved 

electrical connector. Make sure you leave enough wiring in the box to make the 

connection to the fan’s receptacle.

2b.  From where you have chosen to access the fan’s junction box, connect the white wire 

from the house to the white wire from the fan’s receptacle. Connect the black wire 

from the wall switch to the black wire from the fan’s receptacle. Connect the ground 

wire from the house to the green wire from the fan housing 

(Figure 8).

 Use approved 

methods for all connections.

NOTE:

 The fan’s receptacle wires might need to be pulled outside compartment for connection. 

Only pull the four loose wires outside of compartment. Additional wires will be present.

NOTE:

 Unit must be grounded according to all local and national codes.

www.airkinglimited.com

6727900 Rev. D 9-16

3 of 12

Humidity Sensing Models

3a.  For proper operation the humidity sensing fan will require a 3 way switch (not included).  

Run wiring between the fan and the switch location. Make sure you leave enough wiring 

in each box to make the connections. At the switch box connect the black wire from the 

house to the common terminal of the switch. Connect the black wire from the fan to one 

of the switched terminals on the switch. This position will energize the automatic mode 

and the fan will energize upon a rise in humidity. Connect the yellow wire from the fan 

to the other switched terminal on the switch. This position will activate the Manual On 

feature and energize the fan.  Properly connect the ground and neutral (if applicable) 

mount the switch and the cover.

3b.  From where you have chosen to access the fan’s junction box, connect the white wire 

from the house to the white wire from the fan. Connect the wire from the automatic 

position on the wall switch to the black wire from the fan, connect the wire from the 

manual On position on the switch to the yellow wire from the fan. Connect the ground 

wire from the house to the green wire from the fan housing 

(Figure 9).

 Use approved 

methods for all connections. 

 

NOTE:

 The yellow wire may contain a wire crimp nut which will have to be cut off and 

the wire stripped.

4. 

Carefully tuck wire back inside wire compartment and replace wire compartment cover 

securing with the screw that was removed earlier.

SECTION 6

Completing the Installation

1. 

Use a sealant appropriate for contact with the building materials present and for the 

temperature requirements of the installation to prevent air leakage from unconditioned 

spaces is recommended. If gaps between unit housing and ceiling are great, additional 

material (backing rod, ceiling material) may be required.

NOTE: 

This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan 

be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.

2. 

If the fan’s blower assembly was removed during the wiring process, reinstall the 

blower by reversing the directions in 

Section 5

 (Wiring), 

Step 1b.

 

3a. 

STANDARD MODELS: 

Plug the fan’s 

quick connect motor cord into the 

corresponding receptacle located on 

the wire compartment cover. This cord 

will only fit one way into the receptacle 

(Figure 10).

3b. 

HUMIDITY SENSING MODELS: 

Plug the 

fan’s quick connect motor cord into the 

corresponding receptacle located on the 

wire compartment cover. Connect the 

two pin connector from the humidistat 

compartment to the two pin connector 

from the side of the wire compartment 

cover. These cords will only fit one way 

into the receptacles 

(Figure 10).

3c. 

MOTION SENSING MODELS:

 Plug the fan’s quick connect motor cord into the 

receptacle located on the side of the wire compartment cover. Plug the 4 pin quick 

connect cord from the grill into the 4 pin receptacle located on the top of the wire 

compartment cover. These cords will only fit one way into the receptacles 

(Figure 10).

4. 

Install the ceiling mounting flange to cover any gaps which exist between the housing 

and the finished ceiling. Put sealant (not provided) on inside edge of the ceiling 

mounting flange to ensure that the flange is sealed to the ceiling. Line up the screw 

holes in the ceiling mounting flange with the screw holes on the inside of the housing 

and press flange in place so it is tight against the ceiling. Reinstall ceiling flange 

mounting screws inside the housing 

(Figure 11)

.

Figure 5

Screw

Wire 

Compartment 

Cover

Figure 8

Supply from house

Black

Neutral (White)

Ground (Green or Bare)

Fa

n

Switch

Black

Neutral (White)

Green

Figure 9

Supply from house

Black

Neutral (White)

Ground (Green or Bare)

Fa

n

Switch

Black

Neutral (White)

Green

Yellow

Screw

Wire Compartment 

Cover

Figure 7

NOTE:

 Wire compartment configuration 

will be dependent on model.

Figure 10

Motion

Fan

Humidity

Tabs

Screws

Figure 6

34

5

6

7

8 9

101112

13
OFF

(x10)

Содержание D4S

Страница 1: ...ent air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Страница 2: ...the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727900 Rev D 9 16 2 of 12 SECTION 4 Ducting NOTE 6 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong ...

Страница 3: ... to the green wire from the fan housing Figure 9 Use approved methods for all connections NOTE The yellow wire may contain a wire crimp nut which will have to be cut off and the wire stripped 4 Carefully tuck wire back inside wire compartment and replace wire compartment cover securing with the screw that was removed earlier SECTION 6 Completing the Installation 1 Use a sealant appropriate for con...

Страница 4: ...nimum on time to 30 minutes see numbers in Step 2b The sensor will then flash the number of times for the new setting 3 times before exiting back to the programming mode 3 Once all setting have been made and the sensor will return to detection mode and the LED will flash when occupancy of the room is detected SECTION 8 Setting the Humidistat This fan may be equipped with a humidity sensor that aut...

Страница 5: ... does not apply if the product was damaged or failed because of accident improper handling or operation shipping damage abuse misuse unauthorized repairs made or attempted This warranty does not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIE...

Страница 6: ...acement Part 7 1 Grill 5S1202048 8 1 Wire Compartment Assembly 5S1250103 Specific to Model D4SG Qty Description Replacement Part 9 1 Wire Compartment Assembly 5S1250114 15 1 Grill Assembly 5S1239115 Specific to Model D4SH Qty Description Replacement Part 7 1 Grill 5S1202048 10 1 Wire Compartment Assembly 5S1250115 13 1 Knob 5S1299802 14 1 Humidity Sensor Compartment 5S1239826 Specific to Models D4...

Страница 7: ...uit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorités locales du code c Lors de ...

Страница 8: ...es rails aux solives Figure 1 www airkinglimited com 6727900 Rev D 9 16 8 of 12 SECTION 4 Conduits NOTE UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX REMARQUE La canalisation de ce ventilateur à l extérieur du bâtiment a un effet important sur le flux d air le bruit e...

Страница 9: ...ectez le fil de la position automatique sur l interrupteur mural au fil noir du ventilateur connectez le fil de la position manuelle sur l interrupteur au fil jaune du ventilateur Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur Figure 9 Utiliser des méthodes approuvées pour toutes les connexions REMARQUE Le fil jaune peut contenir un écrou de fil à sertir qui devra êtr...

Страница 10: ...de mouvement sur le gril du ventilateur et appuyez sur le bouton 10 fois Le LED sur le capteur clignote alors le nombre de fois pour indiquer le réglage actuel Ceci sera répété 3 fois 1 fois 0 minutes 4 fois 45 minutes 2 fois 15 minutes 5 fois 60 minutes 3 fois 30 minutes 2c Pour ajuster le réglage tandis que le capteur est continue de clignoter de l étape 2b appuyez sur le bouton le nombre de foi...

Страница 11: ...te garantie ne couvre pas les coûts d expédition pour le retour des produits à Air King pour la réparation ou le remplacement Air King payera les frais d expédition de retour de Air King après les réparations ou le remplacement de garantie TOUTES LES GARANTIES EXPRESSES OU TACITES COMPRENANT SANS LIMITATION TOUTE GARANTIE TACITE DE VALEUR MARCHANDE DURENT UN AN DE LA DATE DE L ACHAT ORIGINAL OU JU...

Страница 12: ... 5S1202048 8 1 Assemblée du compartiment du fil 5S1250103 Particularités de modèle D4SG Qté Description de pièce de remplacement 9 1 Assemblée du compartiment du fil 5S1250114 15 1 Assemblée de Grille 5S1239115 Particularités de modèle D4SH Qté Description de pièce de remplacement 7 1 Grille 5S1202048 10 1 Assemblée du compartiment du fil 5S1250115 13 1 Bouton 5S1299802 14 1 Compartiment du capteu...

Отзывы: