Select a Location

CAUTION

Investigate and determine the location of the AC coil prior to drilling holes in 
duct for mounting unit. Use care to avoid damage to the coil and any wiring 
or other components while installing the Haven Plus unit.

WARNING

To prevent water damage or electric shock, do NOT mount unit under 
a humidifier.

1. Determine the air flow direction.

Now that you have located your air handler and where the HVAC 
system is in your home, it is time to choose an install location. 
Choosing the best location is dependent on what layout the 
HVAC system has; Down Flow, Up Flow, or Horizontal Flow.
(Reference Figure B to see which layout matches your HVAC.)

2. Choose a suitable location for the unit.

Possible locations are downstream from the ‘A’ coil (Air 
Conditioning Coil) in the supply plenum OR in the return plenum; 
preferably downstream from the air filter. 
For optimum “cleaning” effect on the ‘A’ coil, mount the unit in the 
supply plenum as close as possible to the ‘A’ coil.
(Reference Figure B to pick the best install location for your 
system’s air flow direction.)

NOTE:

 SEAL the joints and seams of the plenum near the mounting location 

to reduce any direct viewing of UV light.

SELECT A LOCATION

AIR FLO

W

AIR FLO

W

AIR FLO

W

AIR FLOW

Furnace or
Air Handler

Furnace or
Air Handler

Furance or
Air Handler

P/N 46452800 07/03

A C

oil

A Coil

HORIZONTAL  FLOW

Supply

Air Plenum

Floor

Return

Air Plenum

Air+Health™

Best Location

Air+Health

TM

Optional Location

Return

Air Plenum

Supply

Air Plenum

AIR

 F

LO

W

Furnace or 

Air Handler

A Coil

Supply

Air Plenum

Re

turn

A

ir P

len

um

AIR

 F

LO

W

A Coil

DO NOT mount near a 

return air register grill

These units are mounted in attics or crawl spaces.

Only

Location

Supply

Air Plenum

Re

turn R

egist

er

 G

rill

W

all

AIR

 F

LO

W

AIR  FLOW

DOWN FLOW

UP FLOW

Furnace or 

Air Handler

Furnace or 

Air Handler

WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING 
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS. 
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM. 
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.

FIGURE B

Содержание Haven Plus

Страница 1: ...PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY before proceeding with the installation Whole Home Protection Scan QR install guide airhealth com diy installation PLUS INSTALLATION USER MANUAL...

Страница 2: ...nation of photo catalytic chemical reaction and carbon absorption as air passes through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously...

Страница 3: ...o internal contents of lamp wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If y...

Страница 4: ...g this product 7 Screws x4 4 sheet metal screws 8 Alcohol Wipe For cleaning the lamp Tools Required Marker Power Drill Gloves Screwdriver Flat Head Metal Shears Duct Tape MEET YOUR NEW HAVEN PLUS WARN...

Страница 5: ...parate Air Handler in the attic or crawl space A C CONDENSER A C CONDENSER A C CONDENSER A C CONDENSER How to identify your HVAC system type 1 Use Figure A to identify which type of system you have 2...

Страница 6: ...he unit in the supply plenum as close as possible to the A coil Reference Figure B to pick the best install location for your system s air flow direction NOTE SEAL the joints and seams of the plenum n...

Страница 7: ...to duct Hold or temporarily tape the supplied mounting plate in the location chosen for installation and use the plate as a template to mark the duct along the outermost slots in the plate see Figure...

Страница 8: ...bend point See Figure 5 Bend both tabs at the second bend point up and down to pinch and grip the duct material See Figure 6 FIGURE 5 FIGURE 7 FIGURE 6 INSIDE DUCT Duct Board Mounting Duct Board Mount...

Страница 9: ...e unit can be rotated so that the view port is always easy to access Directions for airflow Up Flow The unit should be mounted as shipped Horizontal Flow The entire unit including the ballast should b...

Страница 10: ...C lamp into the ballast assembly lamp socket See Figure 15 7 Wipe off UVC lamp with alcohol wipe Wipe off the lamp glass with the supplied alcohol wipe 8 Insert the UVC lamp and ballast into the mount...

Страница 11: ...the plated washer on the switch is raised approximately 3 16 and the switch is fully engaged See Figure 20 11 Seal all joints and seams With standard duct tape seal any joints and seams near the mount...

Страница 12: ...substrate with solutions Do not attempt to clean the catalytic aluminum substrate core with cleaning solutions The catalyst is radiated with short wave ultraviolet light during period of non air flow...

Страница 13: ...Remove the old lamp from the lamp socket See Figure 24 4 Install replacement UVC lamp Install replacement lamp into lamp socket Do not handle the lamp with bare hands Oils on the hands may reduce lam...

Страница 14: ...and or rotate ballast and repeat step 8 above 9 Dispose of the old UVC lamp according to local regulations UVC lamps contain a small amount of mercury like a typical fluorescent lamp Check with your...