8
9
Select a Location
CAUTION
Investigate and determine the location of the AC coil prior to drilling holes in
duct for mounting unit. Use care to avoid damage to the coil and any wiring
or other components while installing the Haven Plus unit.
WARNING
To prevent water damage or electric shock, do NOT mount unit under
a humidifier.
1. Determine the air flow direction.
Now that you have located your air handler and where the HVAC
system is in your home, it is time to choose an install location.
Choosing the best location is dependent on what layout the
HVAC system has; Down Flow, Up Flow, or Horizontal Flow.
(Reference Figure B to see which layout matches your HVAC.)
2. Choose a suitable location for the unit.
Possible locations are downstream from the ‘A’ coil (Air
Conditioning Coil) in the supply plenum OR in the return plenum;
preferably downstream from the air filter.
For optimum “cleaning” effect on the ‘A’ coil, mount the unit in the
supply plenum as close as possible to the ‘A’ coil.
(Reference Figure B to pick the best install location for your
system’s air flow direction.)
NOTE:
SEAL the joints and seams of the plenum near the mounting location
to reduce any direct viewing of UV light.
SELECT A LOCATION
AIR FLO
W
AIR FLO
W
AIR FLO
W
AIR FLOW
Furnace or
Air Handler
Furnace or
Air Handler
Furance or
Air Handler
P/N 46452800 07/03
A C
oil
A Coil
HORIZONTAL FLOW
Supply
Air Plenum
Floor
Return
Air Plenum
Air+Health™
Best Location
Air+Health
TM
Optional Location
Return
Air Plenum
Supply
Air Plenum
AIR
F
LO
W
Furnace or
Air Handler
A Coil
Supply
Air Plenum
Re
turn
A
ir P
len
um
AIR
F
LO
W
A Coil
DO NOT mount near a
return air register grill
These units are mounted in attics or crawl spaces.
Only
Location
Supply
Air Plenum
Re
turn R
egist
er
G
rill
W
all
AIR
F
LO
W
AIR FLOW
DOWN FLOW
UP FLOW
Furnace or
Air Handler
Furnace or
Air Handler
WARNING: NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE. LOOKING
DIRECTLY AT THE UVC LIGHT MAY CAUSE PERMANENT EYE DAMAGE OR BLINDNESS.
NEVER OPERATE THE AIR+HEALTH™ AIR PURIFYING SYSTEM OUT OF THE PLENUM.
AVOID TOUCHING THE GLASS PORTION OF THE LAMP WITH YOUR HANDS.
FIGURE B