10. After replacing lamp, make sure a new 

Lamp Replacement Label

 (supplied with lamp replacement) is applied to the 

housing and dated with the date of installation. 

NOTE:

   

If blue light leaks through any portion of plenum and/or around mounting plate, unplug power supply cord 

immediately and seal affected areas and/or rotate ballast and repeat step #8 above.

 

11. UV bulbs contain a small amount of mercury, like a typical fluorescent bulb.  Check with your local waste 

management authority for local disposal or recycling requirements.  According to the EPA’s Universal Waste Rule, 
these types of bulbs may be disposed of into household waste. 

WARNING:

 

Never touch broken bulb or internal contents of bulb.  The bulb contains mercury. 

NOTE:  

In case of accidental exposure to internal contents of bulb, wash hands and any other affected skin area 

with mild detergent.  Remove affected clothing immediately.  If skin surface is pierced, seek medical attention 
immediately.

 

TROUBLESHOOTING GUIDE 

1.  Pull back metal washer on mounting base. If lamp comes on, the base needs tightening to ensure that the safety 

switch is fully engaged 

2.  If bulb does not light up, rotate ballast slightly clockwise or counter-clockwise 
3.  If bulb does not light up after rotating ballast, replace bulb. 
4.  If unit still does not light up after replacing bulb, replace ballast.  

REPLACEMENT PARTS LIST 

For replacement parts, contact Home Health Products at: 

!

Phone: 1-866-765-1587 • 

!

Fax: 1-866-253-1029 

$

Email: [email protected] 

CLEAN-UP OF BROKEN BULBS

 

(see warnings on page two of this manual)

 

UV bulbs contain a small amount of mercury, like a typical fluorescent bulb.  DO NOT touch any of the mercury with your 
bare hands. 

1.  While wearing disposable, non-absorbent protective gloves, pick up the large pieces of glass with your hands. 

2.  Then, vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all bulb material. 

3.  Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage bag. 

4.  Check with your local waste management authority for local disposal or recycling requirements.  According to the 

EPA’s Universal Waste Rule, these types of bulbs may be disposed of into household waste.

3

 

5.  Wash hands and remove and wash clothes for added safety measures.

 

 

 

The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.

 

BULB 

(Home Health Products Part  

Number)

 

46444900 

 

WARNING:

 Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent

eye damage or blindness. 

Never operate the Air+Health™ Air Purifying System out of the plenum

. Avoid touching the

glass portion of the bulb with your hands. 

Содержание Air+Health AH-1

Страница 1: ...ion Sheet 1 Fiberglass Duct Board Mounting Bracket 1 1 1 2 Hole Saw 1 Pair of Safety Glasses retain for future use when maintaining this product English Page 1 Fran ais Page 6 Espa ol P gina 10 The Ai...

Страница 2: ...diately In case of accidental exposure to internal contents of bulb wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek...

Страница 3: ...ing template to air duct in either a vertical or horizontal position as shown in Figure 2 Leave template mounted to duct for future reference 3 Drill 1 8 diameter mounting holes at positions indicated...

Страница 4: ...m output intensity replace your Air Health Air Purifying System bulb annually depending upon your home environment using the replacement procedure below The bulb should operate continuously for maximu...

Страница 5: ...does not light up after replacing bulb replace ballast REPLACEMENT PARTS LIST For replacement parts contact Home Health Products at Phone 1 866 765 1587 Fax 1 866 253 1029 Email sales homehealthproduc...

Страница 6: ...a bo te d baller le purificateur et le tube et v rifier s ils pr sentent des signes d avarie Le cas ch ant ne pas proc der l installation Si le tube est endommag fissur ou cass ne pas y toucher ni aux...

Страница 7: ...t d terminez l endroit de l enroulement de A avant les trous de forage dans le conduit pour l unit de montage REMARQUE Pour une installation sur une plaque se r f rer au sac d accessoires contenant la...

Страница 8: ...l inspection au cas o le tube serait cass par inadvertance 1 Il est recommand d inspecter et de nettoyer le tube au moins tous les 6 mois selon les conditions environnementales de la maison l tat des...

Страница 9: ...e la commande de s curit est enti rement engag e 2 Si le tube ne s allume pas tourner l g rement le ballast dans le sens anti horaire 3 Si le tube ne s allume toujours pas le remplacer 4 Si le nouveau...

Страница 10: ...a bombilla rota o el contenido de la misma ya que sta contiene mercurio Despu s de abrir la caja desembale e inspeccione la unidad y la bombilla para ver si tienen da os No instale esta unidad si hay...

Страница 11: ...os agujeros que perforan en el conducto para la unidad de montaje NOTA Para realizar la instalaci n del tablero de conducto refi rase al ensamblado incluido en la bolsa que contiene la plantilla de mo...

Страница 12: ...a bombilla por lo menos cada 6 meses seg n el entorno de su casa condici n de los filtros convencionales duraci n y ciclo de reemplazo 2 Para mantener la m xima intensidad de salida de la bombilla ree...

Страница 13: ...ara asegurarse de que el interruptor de seguridad est contratado completamente 2 Si la bombilla no se enciende gire el reactor levemente hacia la derecha o izquierda 3 Si a n no se enciende despu s de...

Страница 14: ...roduit ou au remboursement du prix de facture si le produit pr sente un vice de mat riel ou de fabrication dans les 90 jours suivant la date d achat L obligation d Home Health Products de r parer ou d...

Страница 15: ...Page 15...

Страница 16: ...1 Richard Riley M D Airborne Infection The American Journal of Medicine September 1974 Vol 57 5 16 01 P N 46445200 Rev C 06 05 PMB 322 9702 Gayton Road Richmond VA 23238 4907 1 866 765 1587 www airhea...

Отзывы: