background image

19

Install indoor unit 

Install the rear panel

1.Always mount the rear panel horizontally. As the water drainage pipe at the left, when

  adjusting the rear 

 panel, this side should not be too high; the right side should be slightly

 high.

2. Fix the rear panel on the selected location

3. Be sure that the rear panel has been
fixed firmly enough to withstand the weight
of an adult of 60kg, furthermore, the weight
should be evenly shared by each screw.

Install the piping hole

1. Make the piping hole in the wall at a slight downward slant to the outdoor 

side.

2. Insert the piping-hole sleeve into the hole to prevent the connection 

piping and wiring from being damaged when passing through the hole. 

Install the water drainage pipe

1. For well draining, the drain hose should be placed at a 
    downward slant. 

2. Do not wrench or bend the drain hose or flood its end 

    by water. 

3. When the long drainage hose passing through indoor, 

    should wrap the insulation materials. 

Wrenched 

Bent

Flooded

Indoor

Outdoor

Wall pipe

Seal pad

Fig.1

(Rear piping hole) 

(Rear piping hole)

Left

Right

Mark on the middle of it 

Gradienter

Space to

the wall 

150mm

above

Space to

the wall 

150mm

above

Wall 

Wall 

Connect indoor and outdoor electric wires 

1. Open the front panel upwardly.

2.Screw off the fixing screw of cover plate and screw off cover plate.
3. Put the power connection cable through the back of indoor unit wire hole and take it out.

4. All the wiring should be connected according to the circuit diagram on the unit.

5. Put the power connection cable the section, which with sheath into wire groove, and 

    cover the cover plate, screw on the fixing screw, tighten the connection wire.

6. Cover the front panel cover.

Содержание Mini Split Air Conditioner

Страница 1: ...r Conditioner Air Con Air Conditioners Thank you for choosing an Air Con air conditioner Please take time to it carefully for future reference read this owner s manual carefully before operating the u...

Страница 2: ...or the items should be followed Emergency operation 10 The figures in this manual may be different with the material objects please refer to the material objects for reference Installation and Mainten...

Страница 3: ...en for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Страница 4: ...or stick into the air intake or outlet vents Don t use the air conditioner for other purposes such as drying clothes preserving foods etc To adjust the airflow direction appropriately When operating...

Страница 5: ...se If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high humidity after a long while running frost will form on outdo...

Страница 6: ...5 2 1 4 3 6 8 7 Names and functions of each part Indoor unit Air in Air out Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Remote control Outdoor unit Air out Air i...

Страница 7: ...s button the setting temp will be decreased by 1 The temp will be changed quickly the button continuously and setting temp range is by pressing Operation of remote control Swing up and down button bel...

Страница 8: ...the setting time range is from 0 5 to 24 hr continuously to change timing value quickly then remote controller will send out the signal immediately and hour on off will stop flickering If the time of...

Страница 9: ...s set the icon will be displayed and the indicator light in the displayer will be off Light button LIGHT Press this button enter into SLEEP state when repressed it will quit The sleep function and FAN...

Страница 10: ...EEP button set the sleep mode 2 Press TIMER button then press button to set the 3 Press light button to control displayer light on or off 4 Press X FAN button to set X FAN function on or off 5 Press t...

Страница 11: ...control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Sketch map for changing batteries NOTE Fig 1 Fig 2 About lock About AU...

Страница 12: ...the unit is running press the ON OFF button of the manual switch the unit will stop work Manual Switch AUTO STOP Displayer indicator light control of indoor unit It s a special selectivebutton for th...

Страница 13: ...front panel and take it out forcibly and then can take it off Washing Clean with a soft brush water and neutral dete rgent and then dry it Note Before cleaning the unit please take down the displayer...

Страница 14: ...e filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 When the filters are very dirty such as oil stain and dry it in the shad...

Страница 15: ...air conditioner is running under cooling mode You may hear a slight crack when the air conditioner is started or stopped The air conditioner itself has no bad smell If any It is the bad smell accumula...

Страница 16: ...of the plug and reinsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote...

Страница 17: ...plug If unit is running under the high humidity for a long time the moisture will be condensed on the air outlet grill and drip off In HEAT mode when the temperature of indoor heat exchanger is very...

Страница 18: ...he height of the installed location should be 230 cm or more from the floor 6 Select a place about 1m or more away from TVset or any other electric appliances 7 Select a place where the filter can be...

Страница 19: ...family power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may cause fire The min distance from the unit and combustive surface is 1 5...

Страница 20: ...Above A b o v e m c 0 3 50cm 0 2 0 15cm 15cm 300 cm 2 15 cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side A b o v e m c 0 2 m c 0 Above 30cm Above cm cm I...

Страница 21: ...ning the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor should wrap the insulatio...

Страница 22: ...routing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping or 1 2 3 Take out the piping from body case wrap the piping electric wire water pipe with tape a...

Страница 23: ...eakage test Liquid pipe Gas pipe Valve cap Vacuum gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut...

Страница 24: ...ion Install the outdoor drain elbow in 25 hole on the base plate and joint the drain hose to the elbow so that the wastewater formed in the outdoor unit can be drained out to a proper place Chasis Out...

Страница 25: ...e earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient cooli...

Страница 26: ...lter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning I...

Страница 27: ...Website www airconpr com Air Con Inc Carr 2 km 16 5 Barrio Candelaria Toa Baja P R 00949...

Отзывы: