1
7
2.Make the power connection wire go through
the cable-cross hole at the back of indoor
unit and then pull it out from the front side.
power connection
wire
cable-cross
hole
3.Remove the wire clip; connect the power
connection wire to the wiring terminal
;
tighten the screw and
then fix the power
connection wire with wire
clip.
4.Put wiring cover back and then tighten the
screw.
5.Close the panel.
Note:
● All wires of indoor unit and outdoor unit
should be connected by a professional.
● If the length of power connection wire is
insufficient, please contact the supplier for a
new one. Avoid extending the wire by yourself.
● For the air conditioner with plug, the plug
should be reachable after finishing installation.
● For the air conditioner without plug, an air
switch must be installed in the line. The
air switch should be all-pole parting and the
contact parting distance should be more
than 3mm.
1.Bind up the connection pipe, power cord
and drain hose with the band.
Step eight: bind up pipe
indoor unit
gas
pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
2.Reserve a certain length of drain hose and
power cord for installation when binding
them. When binding to a certain degree,
separate the indoor power and then
separate the drain hose.
drain hose band
connection pipe
indoor power cord
3.Bind them evenly.
4.The liquid pipe and gas pipe should be
bound separately at the end.
Note:
● The power cord and control wire can't be
crossed or winding.
● The drain hose should be bound at the
bottom.
N(1) 2
3
Outdoor unit connection
Wiring Cover