background image

TABLET

Do not accept android system updates.  To verify that your table is 

set not to accept updates.  Please follow the directions below to 

confirm. 

Note: Tablets ship from Air-Care with updates set to off

Air-Care | 800.322.9919 | [email protected] 

8

June 2018 - Part # FG0179   

Made in the USA

Содержание Bio Cart HEPA-UVC 13 LT

Страница 1: ...Air Care 800 322 9919 cs air care com 1 June 2018 Part FG0179 Made in the USA ...

Страница 2: ...ew 6 Tablet Overview 7 9 Testing of your Bio Cart HEPA UVC 13LT 10 20 Operating your Bio Cart HEPA UVC 13LT 21 24 Safety 25 26 Maintenance 27 30 Compliance 31 Spec Sheet 32 Warranty 33 3868 E Post Road Las Vegas NV 89120 800 322 9919 cs air care com Air Care 800 322 9919 cs air care com 2 June 2018 Part FG0179 Made in the USA ...

Страница 3: ...hat time If the work to be done is a simple re lamping or running a new IT cable the time to evacuate build and remove a temporary containment room is much greater than the time to do the actual work A more efficient way to provide HEPA containment with Negative Pressure for normal work without evacuation was needed therefore the Portable Containment Cart was developed It is rolled into place plug...

Страница 4: ...sturbing paperwork on tables and desks in the area the ladder lowers inside the cart so it can be moved without making a second trip to move a step ladder that may be too tall to remain inside the Bio Cart while moved Tablet based manometer reads and calculates the number of air changes per hour provided by the air scrubber blower and HEPA filter This is displayed on the right side of the tablet s...

Страница 5: ...PA UVC 13LT needs to be returned due to damage you will need the packaging to repack Carefully lift the Bio Cart HEPA UVC 13LT from pallet with appropriate fork Lift and place on smooth level surface Ensure brakes are set on wheels before leaving the Bio Cart HEPA UVC 13LT unattended Once unpacked please inspect the interior of the Bio Cart HEPA UVC 13LT for any signs of damage this includes the b...

Страница 6: ...CONTROL PANEL Air Care 800 322 9919 cs air care com 6 June 2018 Part FG0179 Made in the USA ...

Страница 7: ...TABLET Air Care 800 322 9919 cs air care com 7 June 2018 Part FG0179 Made in the USA ...

Страница 8: ...dates To verify that your table is set not to accept updates Please follow the directions below to confirm Note Tablets ship from Air Care with updates set to off Air Care 800 322 9919 cs air care com 8 June 2018 Part FG0179 Made in the USA ...

Страница 9: ...TABLET Continued Air Care 800 322 9919 cs air care com 9 June 2018 Part FG0179 Made in the USA ...

Страница 10: ...io Cart HEPA UVC 13LT may require the ladder to be removed to perform some of the tests Test the brakes on the 2 wheels with brakes to ensure they will secure the cart in working position Test the swivel locks on the 2 caster wheels Lock the swivel and engage a wheel brake at the same time Air Care 800 322 9919 cs air care com 10 June 2018 Part FG0179 Made in the USA Front wheel back wheel ...

Страница 11: ...oxes are below the Pre filter The IN USE light Switch on the Control Panel The Interior Light Switch on the Control Panel Turn the Air Scrubber Motor Speed Control to OFF fully CCW on the Control Panel Turn the Battery Switch OFF The tablet charging cord can remain connected Air Care 800 322 9919 cs air care com 11 June 2018 Part FG0179 Made in the USA ...

Страница 12: ...oor Inspect the GFI power plug for damage Pull the power cord out several feet give it some slack and it should lock in place Pull the cord tight again and allow it to be pulled in and rolled up into the cart Air Care 800 322 9919 cs air care com 12 June 2018 Part FG0179 Made in the USA ...

Страница 13: ...wer cord is in a live properly grounded outlet make sure the GFI is plugged into a live outlet and the GFI green indicator is on When the BLUE panel meter is on turn on the IN USE light switch and verify that the IN USE light on the outside of the door is lit Air Care 800 322 9919 cs air care com 13 June 2018 Part FG0179 Made in the USA ...

Страница 14: ...ill turn on If it does not leave the switch on until you test the UVC interlock switch When the UVC lamps are ON the Blower should run but when the HEPA replacement door on the outside is open the UVC lamps and the blower will not turn on Air Care 800 322 9919 cs air care com 14 June 2018 Part FG0179 Made in the USA ...

Страница 15: ...io Cart HEPA UVC 13LT will begin to rise with the yellow and black bellows RELEASE the switch and it will stop When raising it to the ceiling release the button just as the foam touches the ceiling to prevent any damage to the ceiling or the cart Press the DOWN Bottom of the rocker switch and the RED light will light and the top will lower back to the transporting position Release the button when ...

Страница 16: ...orward a few inches and out of the bottom retainer Be sure to have the side retainer strap in place as you carefully remove the ladder from the cart When reinstalling the Ladder verify that the feet are in the floor retainers and secure the upper clamps Next remove the Pre Filter in the Air scrubber section and note the location of the Circuit Breaker Button on the side of the Retractable Power Co...

Страница 17: ...cause eye damage so there is an interlock switch on the external HEPA door that will turn them off when changing the HEPA filter even if the operator forgets to turn them off Go to the outside of the cart and open the HEPA access door at the bottom of the rear panel by turning the latches and lowering it to be sure the UVC lights and the Air Scrubber Fan turn off as it is opened Air Care 800 322 9...

Страница 18: ...ir care com 18 For maneuvering the Bio Cart HEPA UVC 13LT through lower doors you may need to reposition the ladder base near the door after loosening the upper clamps Retighten the upper clamps to secure the ladder in position NEVER CLIMB THE LADDER IN THIS POSITION The Feet MUST BE IN THE FLOOR RETAINERS WHEN USING THE LADDER June 2018 Part FG0179 Made in the USA Lower ladder retainers ...

Страница 19: ...Exterior LED lighting is viewable on 3 sides of the cart to alert occupants to the activity in the area The lights have 3 modes Orange ON continuously Orange pulse or solid Blue The camera and light strips will be most effective while the cart is being moved within the building The onboard battery will provide 2 hours of operation if fully charged The Battery Switch on the control Panel must be ON...

Страница 20: ... stops immediately when released DO NOT HOLD THE BUTTON after it reaches the ceiling or when it is fully down this will put strain on the motors There is a limit circuit on the motors to reduce the torque once it has contacted a solid surface The tablet should be mounted on the window brackets for observing the camera when the Bio Cart HEPA UVC 13LT is being moved and a clamp with articulated arm ...

Страница 21: ...ernal battery while The Bio Cart HEPA UVC 13LT is plugged into the wall Step inside the door close it and press the UP button on the control panel located near the door on the left wall or use the tablet When the foam seal touches the ceiling release the button If the top is raised too far the ceiling may be damaged Turn battery switch to OFF to charge the internal battery The air scrubber motor c...

Страница 22: ...s air care com 22 June 2018 Part FG0179 Made in the USA Bellows up and down Air scrubber motor control Bellows up and down Air scrubber motor control On Off You can only control the speed from Control panel see above Tablet Control Box ...

Страница 23: ... please turn them on now A head mounted work light and a 120 volt halogen work light are included to illuminate the working area above the ceiling There is a power outlet on the control panel and a second power outlet near the tool box shelf Both power outlets include USB connectors for convenient charging of smart devices Before opening the ceiling put on your PPE safety glasses dust mask disposa...

Страница 24: ... a plastic bag inside the cart Step outside the Bio Cart HEPA UVC 13LT and close the door securely It can be locked using the key provided with your Bio Cart HEPA UVC 13LT If required install the top cover of the Bio Cart HEPA UVC 13LT and secure with the velcro straps before it is moved to the next work area This Top is NOT durable enough for transporting the Bio Cart HEPA UVC 13LT in an open tra...

Страница 25: ...e The Ladder MUST be fully seated into the bottom Brackets and the upper support is secured to the ladder with the Clamps provided on the support prior to the technician stepping on to the Ladder When moving the Ladder it must be secured with the strap and snap lock attached to one side This will hold the 3 sections of ladder in a stable configuration while being moved To move the Bio Cart HEPA UV...

Страница 26: ...ust be repaired immediately The top of the Bio Cart HEPA UVC 13LT is raised and lowered with a powered actuator As with all mechanical devices use caution when operating it and keep all materials clear of the moving parts of the actuator If you have any questions regarding the safe and reliable operation of the Bio Cart HEPA UVC 13LT contact Air Care 800 322 9919 or cs air care com Air Care 800 32...

Страница 27: ...re required Consult with the staff in the planned work areas for detailed Infection Control procedures Contact Air Care if you have questions about how to meet specific requirements Generally cleaning the inside of the cart after each use is recommended With the Air Scrubber running the air in the Bio Cart HEPA UVC 13LT is HEPA filtered It is recommended that the air scrubber is left running while...

Страница 28: ... The top layer is black woven electrostatic polypropylene These are disposable and should both be replaced when soiled Odor adsorbing carbon pad can be placed behind the standard 2 layers This pad cannot be washed it must be replaced when dirty or the activated carbon has become fully loaded There is LESS air flow when the carbon pad is in place so unless there is a need to remove odors it does no...

Страница 29: ...ve the box and the bulb Press the Red Release button on the bulb socket and dispose of the bulb in the proper manner for other Fluorescent bulbs with mercury It is best to replace both bulbs at the same time Do NOT touch the glass on the new bulb with your hands oil from your fingers will cause local heating and early failure of the bulb Use rubber gloves or other means to hold the new bulb press ...

Страница 30: ...Air Care if there are any questions on how to replace or adjust it Routine Inspection of the Ladder and its supports Inspect the ladder itself for any missing or loose rivets or other parts Look for cracks in the side rails and the steps If these are present replace the ladder The Ladder Supports in the Bio Cart HEPA UVC 13LT must be in good working order with no missing or damaged parts Check the...

Страница 31: ...containment cart that extend to any ceiling 13 ft 2 in high with a ladder that remains inside to reach the work area The Bio Cart HEPA UVC 13LT provides negative pressure and air exchange rates to comply with CDC guidelines to contain dust and infectious particles Bio Cart HEPA UVC 13LT adds UVGI irradiation in the HEPA Filter compartment to neutralize infectious particles captured by the 99 97 HE...

Страница 32: ...Air Care 800 322 9919 cs air care com 32 June 2018 Part FG0179 Made in the USA ...

Страница 33: ...ir Care will pay FedEx ground shipping charges on the repaired or replaced item back to the purchaser s location Any additional expedited service charges for quicker shipping shall be the responsibility of the purchaser If the product or component is not found to be a warranty issue the purchaser will be responsible for return shipping charges No product or component can be returned without first ...

Отзывы: