![Air Burners S-100 SERIES Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/air-burners/s-100-series/s-100-series_operating-manual_2873755002.webp)
S
-
100 Refractory Walled Air Curtain Burner with HATZ 3H50TIC Diesel Engine
OPERATING MANUAL
WARNING:
1
Should any repairs become necessary that require
welding on your FireBox, you MUST first physically
remove the Electronic Control Module (ECM) from the
computer controlled Diesel engine.
1
Follow the instructions below.
Page i
ECM Removal Steps
1.
Unsnap Latches 1 and 2
2.
Remove Bolts A1 and A2
3.
Unplug both connectors
4.
Remove Bolts B1, B2, B3 and B4
5.
Remove the two brackets
6.
The ECM can now be removed and stored away
7.
Re
-
install all in reverse order.