Air Burners, Inc.
BurnBoss Series Air Curtain Burner (Kubota Z482
-
E3 Engine)
OPERATING MANUAL
(Vers. 08.08.2017)
Page 23 of 27
ASH REMOVAL
HOW TO EMPTY THE BURNBOSS UNITS
We recommend removing the ash every morning before burning operations begin.
This will give you maximum capacity in the FireBox and the ash will be easier to han-
dle.
The box will operate with up to 1.5 feet of ash inside, but as the ash gets deeper the
efficiency of the unit goes down. One and half feet of ash would represent approxi-
mately 35% of the FireBox capacity that would be unusable.
The ash is emptied by raising the FireBox and towing the machine forward. It is im-
portant to tow the machine away from the embers as soon as it is raise to prevent hot
embers form damaging wheels, tires and axles. The machine should be towed for-
wards as the tires can not be driven through the hot embers
Ash Removal
1)
Engine off
2)
Connect tow vehicle
3)
Raise jack stand
4)
Raise FireBox into full up position and IMMEDIATELY pull forward leaving the hot
embers and ash behind.
5)
Insure the ash pile is not left HOT, use water to ensure all fire is out.
6)
Ash can be land applied or loaded in a dumpster for removal.
DANGER:
When removing ash from the FireBox, move the ma-
chine as soon as the FireBox is raised to prevent the hot embers
from damaging the wheels, tires and axles.
DANGER:
When removing ash from the FireBox, be aware of
the wind direction and insure all operators wear appropriate face
masks to prevent inhaling the ash.