background image

– 9 –

5

5

MOUNTING

TC-(10,20)M with TC-(20,40)G

Remove 2 screws on front panel, removing the cover on upper end and area/section plate. Lift off front
case holding sides at top. Disconnect the intercom by unplugging the connector.
Open a cable inlet hole (rubber part) on bottom of chassis. Pull in cable(s), and make wire terminations.
Use attached cable clamps(s) for neat and secured connection. Reconnect and mount front case to
chassis, attaching the cover and plate in place.

When wall-mounting, separate the front panel from chassis, as explained above.  Install the chassis
upside down on the wall, onto a single-gang or two-gang box.

TC-M master wall-mounts with TC-G (and TB-AD10) attached.

Decide the exact location of TB-M master, and use the following measurements to mount the add-on components.

Connecting a buzzer at a TB-SE sub

When called by TC-M master, buzzer is
activated and on TB-SE sub, call tone sounds
at reduced volume.
TAR-3 relay activates an AC-operated buzzer:
AC 240V, 0.3A.  DC-operated buzzer must be
mechanical type: DC 24V, 1.0A.  
Do not use DC electronic buzzer.

Area / section plate

Lift off front case holding
sides at top.

Screws

Cover

Open a knock-out
hole.

Lift off front case holding sides
at top.

Screws

Single-gang or
2-gang box

Chassis mounts upside down.

83.5 mm,
3-5/16"

TC-M

master

TB-SE

sub

TAR-3

DC6V, 160mA

To : power source

White

Orange

Blue

Orange

Red

Black

White (–)

PS-6D

power supply
(SKK-620
  in USA)

Red (+)

Remove
shorting link.

Buzzer

1
2

3
4

1

E

+

TC-M master

TC-G add-on 
selector

TB-AD10 door 
adaptor

Centers of each chassis

(or gang boxes)

A

B

Desk-top mounting

Wall-mounting

Wall-mounting guide

Master

Attached

Guide A

Attached

Guide B

Attached

Guide A

Attached

TC-20G

202.5, 8"

TB-AD10

150.0, 6"

202.5, 8"

TB-AD10

TC-10M

TC-40G

277.5, 11"

TB-AD10

225.0, 9"

TC-40G

277.5, 11"

TB-AD10

TB-AD10

202.5, 8"

–––

–––

202.5, 8"

–––

TC-20G

240.0, 9-1/2"

TB-AD10

150.0, 6"

TC-20M

TC-40G

315.0, 12-1/2" TB-AD10

225.0, 9"

TB-AD10

240.0, 9-1/2"

–––

–––

Содержание Tc-10m

Страница 1: ...r SA 1 is available from Aiphone 1 Do not connect any power source other than specified on TC M master Fire or damage to the unit could result 2 Do not open TC M master High voltage is present inside...

Страница 2: ...g relay TAR 3 IF DA TC 10M TC 20M TC 20G TC 40G TB SE TB SE R IER 2 TAR 3 TB AD1 TB AD10 IF DA PS 18C PS 18E 10 call master 20 call master 20 call add on selector 40 call add on selector Handset sub s...

Страница 3: ...ide of master Features TC 20G or TC 40G add on selector connects additional TB SE subs allowing system expansion One or dual master configuration TB AD1 adaptor connects TC M with an IE IF Series audi...

Страница 4: ...om TB SE terminal 2 2 wires from TB SE subs must not be made common at any other point than on the TC M terminal block 1 12V 2 3 4 5 6 7 8 9 10 E E E E E E C M R R T T S S 1 12V 2 3 4 5 6 7 8 9 10 E E...

Страница 5: ...sub s station number numbered from the top on each 10 button row 2 parallel wires per TB SE sub nonpolarized Be sure to run each pair of wires directly to TC M master E line in each pair should not be...

Страница 6: ...3 1 2 E 4 1 2 E 5 1 2 E 6 1 2 E 7 1 2 8 1 2 E 9 1 2 10 1 2 TB SE Sub station TC 10M Master station S S Connector To power supply Do not connect any power source here IN AC 15 16V or DC18V 12V OUT Desi...

Страница 7: ...D6 1 2 E D7 1 2 D8 1 2 E D9 1 2 D10 1 2 IF DA E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 E 1 2 1 2 1 2 3 4 5 6 7 8 9 10 12V T R S S To power supply Do not connect any power source here IN AC 15 16V or...

Страница 8: ...larized To power supply Do not connect any power source Designate any terminal for TB AD1 Call extension IER 2 1 E Call extension IER 2 1 E Common TB SE sub rings two TC M Masters Each master can call...

Страница 9: ...zer is activated and on TB SE sub call tone sounds at reduced volume TAR 3 relay activates an AC operated buzzer AC 240V 0 3A DC operated buzzer must be mechanical type DC 24V 1 0A Do not use DC elect...

Страница 10: ...ll TC M leaves sub A waiting pressing a sub B select button When sub B picks up the call sub A hears a busy tone TC M depresses Transfer switch TC M then reselects waiting sub A with red LED on Three...

Страница 11: ...eive and call tone volume Upper control adjusts handset receiver volume when TC M does not hear a TB SE sub clearly Tone control adjusts ringing tremolo 3 levels TC M dual master system Two masters ca...

Страница 12: ...be responsible for any costs incurred involving on site service calls 8 8 SPECIFICATIONS Power source DC18V 350mA max or AC 15 16V 50 60Hz 750mA max Power consumption 6W max 3W standby Capacity 60 sta...

Отзывы: