background image

AIPHONE CO., LTD., NAGOYA, JAPAN

http://www.aiphone.net/

Issue Date: Feb. 2016
FK2243  A   P0216 SZ 57290

Warranty

Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for 
a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it 
become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto 
itself the sole right to make the 

fi

 nal decision whether there is a defect in materials and/or workmanship; and whether or 

not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to 
misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have 
been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries 
used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop 
or place designated in writing by Aiphone. This warranty is limited to the standard speci

fi

 cations listed in the operation 

manual. This warranty does not cover any supplementary function of a third party product that is added by users or 
suppliers. Please note that any damage or other issues caused by failure of function or interconnection with Aiphone 
products is also not covered by this warranty. Aiphone will not be responsible for any costs incurred involving on site 
service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of 
its products during use, or for any consequent inconvenience or losses that may result.

The object area of 

 is the EU.

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause 
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

• 

IC
CAN ICES-3 (B)/NMB-3(B)

Содержание NIM-20B

Страница 1: ...our communication needs Please make sure to read this manual for safe and correct use of the system and keep it in a safe place for future reference Please note that images and illustrations depicted...

Страница 2: ...USING THE SYSTEM AT THE MASTER STATION 11 Answering a call 11 When receiving a single call 11 When receiving multiple calls 12 Calling sub stations 13 Calling a single sub station 13 Paging 14 Adjusti...

Страница 3: ...electric fields GENERAL PRECAUTIONS 1 The unit is inoperative during power failure 2 In areas where broadcasting station antennas are close by this system may be affected by radio frequency interferen...

Страница 4: ...North America only Call extension speaker IER 2 Power supply unit IS PU only PC for call log software NI SOFT Corridor light single bed NIR 4 NIR 4 Call reset button NIR 2 NIR 2 Ceiling speaker NI LB...

Страница 5: ...ods The following two methods are available on the master station Method Communication style Description Using handset Voice actuated communication The communication mode is VOX half duplex When speak...

Страница 6: ...nes audio from a sub station and alarms are heard from here Turn off the POWER switch when the system malfunctions Microphone Sends audio from this station to other stations OFF button OFF Press to en...

Страница 7: ...ed Lights up while calling the master station Microphone RECEIVE VOL Adjusts the volume of audio from the master station to 3 levels low mid high Handle Wall jack with hanger for NI RC NIR HPF Hanger...

Страница 8: ...hone for NIR 8 NIR MB Call latching wall jack for NIR 8 NIR 7BS Call indicator red Speaker Microphone Wall jack for NIR 8 NIR 1 Bedside call switch NIR 8 Connect and fasten the plug to a wall jack Wal...

Страница 9: ...single bed NIR 4 Corridor light multiple beds NIR 4S Call reset button NIR 2 Corridor light with reset button NIR 42 Corridor light with buzzer NIR 4BZ Lamp red Lamp red Reset button Buzzer Pull cord...

Страница 10: ...responding sub station Nameplate See below Room number plate See below Lamp red Reset button Corridor light with nameplates 2 names NIR 32 Corridor light with nameplate 1 name NIR 31 Room number plate...

Страница 11: ...more call indicators are lit on a corridor light pressing the reset button turns off all the indicators USING THE SYSTEM AT THE MASTER STATION The ringtone sounds The call in talk indicator for the c...

Страница 12: ...s the reset button for the calling station The call indicator on the calling station and the corresponding indicators on the master station turn off When two or more call indicators are lit on a corri...

Страница 13: ...begin talking NIM system To speak Press and hold TALK while speaking To listen to the user of the sub station Release TALK while listening To end the communication press 3 OFF NIM system The call in t...

Страница 14: ...peaking NIM system Do not release TALK until you end speaking A notice sound is heard at all the sub stations To end the paging press 3 OFF NIM system NOTES Paging will end automatically after 90 seco...

Страница 15: ...ent communication There is communication only if a sub station or speaker microphone is installed in the calling location While speaking on the master station the TALK indicator is lit audio from the...

Страница 16: ...ly after 90 seconds Calling the master station Press the call button 1 The type of call button differs depending on the equipment used in your application When the master station answers begin talking...

Страница 17: ...s SPCC Color Panel White Chassis Green mist Dimensions NIM 20B 330 W x 230 H x 140 D mm 13 W x 9 1 16 H x 5 1 2 D NIM 40B 480 W x 230 H x 140 D mm 18 7 8 W x 9 1 16 H x 5 1 2 D 60 call 630 W x 230 H x...

Страница 18: ...lbs Bedside call switch NIR 8 Ambient temperature 0 40 C 32 F 104 F Material Plastic Color White Dimensions 36 x 95 H mm 1 7 16 x 3 3 4 H Weight Approx 90g 0 2 lbs Wall jack for NIR 8 NIR 1 Ambient t...

Страница 19: ...ht Approx 85g 0 19 lbs Corridor light with reset button NIR 42 Power source Supplied from the master station Ambient temperature 0 40 C 32 F 104 F Mounting Wall flush mount Electrical box 2 gang box M...

Страница 20: ...will not be responsible for any costs incurred involving on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products dur...

Отзывы: