background image

4

PRECAUTIONS

    

 Prohibited                        

 Do not dismantle unit                         

 Keep unit away from water                        

 General precautions  

WARNING

Negligence could result in death or serious injury.

1. Do not dismantle or alter the unit. Fire or electric shock could 

result.

2. Keep the unit away from water or any other liquid.

Fire or electric shock could result.

3. High voltage is present internally. Do not open the case. 

Electric shock could result.

4. Do not connect any non-speci

fi

 ed power source to the +, - 

terminals. Also, do not install two power supplies in parallel to a 
single input. Fire or damage to the unit could result.

5. Do not connect any terminal on the unit to an AC power line. 

Fire or electric shock could result.

6. Do not use power supply with a voltage other than speci

fi

 ed.

Fire or electric shock could result.

7. Keep AC cord from being marred or crushed. If the AC cord is 

damaged, 

fi

 re or electric shock could result.

8. Do not plug or unplug unit with wet hands. Electric shock could 

result.

9. Insert AC plug completely and securely into AC outlet. 

Otherwise, 

fi

 re or electric shock could result.

10. Periodically check for and remove dust on the power plug. If 

dust is left, it could cause the power plug to heat up, resulting in 

fi

 re.

11. Do not put any metal or 

fl

 ammable material into the unit 

through the openings. Fire, electric shock, or unit trouble could 
result.

12. The unit must be installed and wired by a quali

fi

 ed technician.

CAUTION

Negligence could result in injury or damage to property.

1. Do not install or make any wire terminations while power 

supply is plugged in. It can cause electrical shock or damage to 
the unit.

2. When mounting the unit on a wall, install the unit in a 

convenient location, but not where it could be jarred or 
bumped. Injury could result.

3. Before turning on power, make sure wires are not crossed or 

shorted. Fire or electric shock could result.

4. Do not install the unit in locations subject to frequent vibration or 

impact. It may fall or tip over, resulting in damage to the unit or 
personal injury.

5. For power supply, use Aiphone power supply model speci

fi

 ed 

for use with system. If non-speci

fi

 ed product is used, 

fi

 re or 

malfunction could result.

6. Do not put anything on the unit or cover the unit with cloth, etc. 

Fire or unit trouble could result.

7. Do not perform a touchscreen operation with a sharp 

instrument such as a ballpoint pen or other metal objects. The 
touchscreen may get broken causing leakage of the liquid 
crystal inside the screen. If you get the liquid crystal in your eye 
or mouth, wash it away immediately.

8. Do not install the unit in any of the following locations. Fire, 

electric shock, or unit trouble could result.

Places under direct sunlight or near heating equipment that 

varies in temperature.
Places subject to dust, oil, chemicals, hydrogen sul

fi

 de (hot 

spring).
Places subject to moisture and humidity extremes, such as 

bathrooms, cellars, greenhouses, etc.
Places where the temperature is low, such as inside a 

refrigerated area or in front of an air conditioner.
Places subject to steam or smoke (near heating or cooking 

surfaces).
Where noise generating devices such as dimmer switches or 

inverter electrical appliances are closeby.

9. Do not apply high pressure on the screen. If fractured, injury 

could result.

10. If the LCD is punctured, do not touch the liquid crystal inside. 

In

fl

 ammation could result. If contact should occur, 

fl

 ush or rinse 

area with water thoroughly and consult your doctor.

11. Do not use the handset when you perform a call test, otherwise 

it may cause damage to your ear. Be sure to use the built-in 
speaker.

12. Be sure to perform a call test with the handset on the hook. If 

you operate the hook switch with the handset on your ear, a 
sudden call etc. may arrive causing damage to your ear.

GENERAL PRECAUTIONS

1. Keep the unit more than 1m (3.3') away from radio or TV sets.
2. Keep the intercom wires more than 30cm (12'') away from AC 

100-240V wiring. AC induced noise and/or unit malfunction could 
result.

3. Comply with all third party manufacturing speci

fi

 cations that will be 

used with this system (sensors, door releases, etc.).

4. If the unit is down or does not operate properly, unplug the power 

supply or turn off the POWER switches.

5. When wall-mounted, the top of the unit may darken. This does not 

indicate a malfunction.

6. The unit case may become warm with use, but this is not a unit 

malfunction.

7. If it is used close to a cellular phone, the unit may malfunction.
8. The unit can be damaged if dropped. Handle with care.
9. The unit will not work during power failure.

10. In areas where broadcasting station antennas are close by, the 

intercom system may be affected by radio frequency interference.

11. All the units, except for door stations, are designed for indoor use 

only. Do not use at outdoor locations.

12. Please note the LCD panel, though manufactured with very high 

precision techniques, inevitably will have a very small portion of its 
image elements always lit or not lit at all. This is not considered a 
unit malfunction.

13. Environmental sound around the unit may hinder smooth 

communication, but this is not a malfunction.

14. The unit has audio monitoring function between residential 

stations. When using this function for baby monitoring, never 
install the unit within reach of children to prevent strangulation with 
coil cord or wires.

Содержание JM-4HD

Страница 1: ...r safe and correct use of the system and keep it in a safe place for future reference Please note that images and illustrations depicted in this manual may differ from the actual product JM 4HD HANDS...

Страница 2: ...5 Setting the PIN GENERAL PIN SETTING 15 Call settings CALL 15 Designate door stations allowed to call in to this station DOOR STATION SETTINGS 15 Designate residential station s that receive a call f...

Страница 3: ...CALLING MONITORING OTHER STATIONS 23 Calling all residential stations simultaneously 23 Calling another residential station 23 Monitoring 24 Monitoring door station entrance 24 Monitoring residential...

Страница 4: ...all the unit in any of the following locations Fire electric shock or unit trouble could result Places under direct sunlight or near heating equipment that varies in temperature Places subject to dust...

Страница 5: ...blurry image but this is not a malfunction Normal operation will be restored when moisture evaporates 26 When the unit s screen is illuminated with strong light the image looks white or silhouetted bu...

Страница 6: ...o not bend the cables to an extent where the radius is less than 25 mm 1 Communication failure could result Do not remove the CAT5e cable jacket more than necessary This unit is not a computer periphe...

Страница 7: ...ich they are to be connected For connecting other manufacturers products refer to the instruction manuals for those products The positions of the terminals on the above illustrations differ from the a...

Страница 8: ...A Voltage between terminals Less than 5 V DC when open between terminals 2 3 External door release input 1 2 Connect a door release button to each pair of these inputs Input method N O or N C dry clos...

Страница 9: ...e the cover and then slide it to the left until it clicks Make sure the cover is locked Surface wiring When the wiring is not coming through the wall the cable and wires can be routed through the top...

Страница 10: ...p has been performed the display returns to HOME window A notice message is displayed You can release the HOME button Touch 3 ENTER to continue The INSTALL menu window is displayed Program the setting...

Страница 11: ...until 2 highlighted Touch 3 ENTER to save ID When ID is changed this station will be rebooted Initializing station INITIALIZE By initializing this station all settings return to default From th 1 e IN...

Страница 12: ...lue Blinking every 0 5 seconds Rebooting Handset Color LCD touchscreen See the next page for details Status LED Indicates current status of this station by lighting up or blinking See the table below...

Страница 13: ...ation or another residential station SETTINGS P 14 Touch this to program settings and adjustments OFF Touch this to turn screen off and set this station in standby mode OPTION P 26 Touch this to activ...

Страница 14: ...SETTINGS 1 DOOR1 DOOR2 DOOR3 DOOR4 ENABLE DISABLE ENABLE for each ROOM STATION CALL SETTINGS 1 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 The ID number of this station is not displayed ENABLE DISABLE ENABLE for...

Страница 15: ...ou must keep the PIN without fail If you forget the PIN you must initialize this station by the INSTALL menu thus all the setting contents return to default Call settings CALL You can make the followi...

Страница 16: ...ws the station to receive a call from this station DISABLE Does not allow the station to receive a call from this station Repeat for other stations 4 Use or to scroll between ID numbers When the setti...

Страница 17: ...t and disabled From HOME window touch 1 SETTINGS GENERAL DOOR RELEASE Enter the 4 digit PIN by using the touchscreen then 2 touch ENTER DOOR1 to DOOR4 are displayed If a wrong PIN has been entered an...

Страница 18: ...t Communication also ends automatically after 1 minute in hands free mode or after 3 minutes using handset NOTE If this station is not set to receive a call from a specific door station there will be...

Страница 19: ...ng becomes enabled automatically Communication ends automatically after approx 10 minutes The ID number of the calling station will not be displayed If another residential station is calling all the o...

Страница 20: ...creen Adjusting screen brightness You can adjust the brightness of the screen in 10 levels Touch 1 MENU IMAGE The setting window appears Touch 2 or to change the level Adjusting viewability of images...

Страница 21: ...setting window appears Touch 2 or to reach desired level Door release DOOR RELEASE Door release can be activated during a call in communication or while monitoring a door station Release a door when...

Страница 22: ...tween you and the door station ends When someone touches 5 TALK or lifts handset on the target station he or she can talk with the door station side If handset is lifted in step 3 hang up once and the...

Страница 23: ...m the target stations cannot be heard If someone touches 5 TALK or lifts handset at one of the target stations communication between this station and the target station is initiated To complete commun...

Страница 24: ...n is automatically activated on door station depending on settings Monitoring residential station Audio only You can monitor sounds at another residential station Press the HOME button touch screen or...

Страница 25: ...ID number is shown the status LED blinks in red and an alarm sounds on all the residential stations NOTES The alarm sounds in the maximum volume 10 even if the volume of call tone is set to 0 Door st...

Страница 26: ...This is available when one or two door release buttons are connected to the external door release inputs 1 and or 2 of this station The door at the door station 1 or 2 or both doors can be unlocked b...

Страница 27: ...gets out of commission reboot this station by pressing the reset button SPECIFICATIONS Power supply DC 24V from power supply Current consumption 200 mA Communication Handset Simultaneous communication...

Страница 28: ...ide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses that may result The object area of is the EU F...

Отзывы: