9
1.
Open the cover and use an
open end wrench (or torque ad-
justment tool on quick change
models) to rotate the square
drive until the adjust hole posi-
tion appears below the cover.
2.
Turn the torque adjustment tool
clockwise to increase the torque
and counterclockwise to de-
crease the torque.
Press
Increase
Decrease
Adjust Hole
Cover
Square Hole
7.
Delivered torque to the applica-
tion may vary due to the type of
joint the tool is tightening. Good
practice is to perform periodic
audits of the application.
Audi-
tor™ Torque Wrenches or
Rotary Transducers
are ideally
suited to make these checks.
Forward/Reverse Rotation
Switch Operation
To prevent damage, do not press
Forward/Reverse button until the
tool comes a complete stop.
Forward Rotation Operation
The tool is in forward operation if
the blue light is not on.
Reverse Rotation Operation
By long pressing the F/R switch,
users are able to choose the mode
of reverse operation, either auto-
matic or manual.
Mode 1: Automatic – Tool re-
turns to forward operation auto-
matically after reverse operation.
Mode 2: Manual – Tool needs to
be adjusted manually to return to
forward operation after reverse
operation.
Steps for Torque Adjustment
NOTE:
Remove the battery pack
before adjusting the torque to avoid
injury.