8.5 Starting the Tool
WARNING: Always keep hands clear of the reaction arm when the tool is in use
or serious injury could result.
To operate the tool:
1. Select the desired operating mode: torque mode, gear mode, preset
mode, preset gear, or angle mode.
2. Select Fwd or Rev operation direction
3. Press the trigger firmly. The trigger can be released at any time to stop
the tool and cancel the torque cycle.
Clockwise
operation
Reaction Point
Counter-clockwise
operation
Reaction Point
4. When “Rdy” is displayed on the screen, the tool is ready for the next
torque.
WARNING: Do not continue tightening or loosening directly after
tightening, or tighten objects that exceed the target maximum torque
value, which will cause overload and damage to the tool.
WARNING: Do not continue operation if the gearbox is making an
abnormal noise during the tightening process. Abnormal tool operation
may cause burn out of the motor or the control board.