CHAPTER 5
40
41
MX STRADA SERIES
To set the new alarm:
n
define the Alarm name
(1)
n
a combination of Alarm conditions can be set: choose if the conditions are to be ALL
valid or just one of them
(2-4)
n
decide which action is to be trigged
(5)
among displaying a message or a timed popup
message, display a measure, switch a LED on or activate an output signal
(CAN output page, see the related paragraph)
n
decide the alarm ending condition (“Untill” –
6
) among: condition no longer met, the
device is turned off, a button is pushed or data are downloaded
n
“+” buttons right of the panel are to add new alarms (the top one) or to add new actions
to an alarm (bottom one)
n
when all operations have been performed press “Save” in “Create New Alarm” Panel and the
software comes back to “Shift Lights and Alarm” page.
“Trigger Command” executes some specific actions on MX Strada series.
The commands available up to now are:
n
set next/previous page
n
show camera input page
n
reset alarms
n
activate pushbuttons (1- 4)
Other commands will be available in the next software/firmware releases.
To add a new command.
n
Press “Add new Command”
(1)
n
a combination of conditions are allowed for setting a Trigger Commands and it is possible
to decide whether the conditions are to be ALL valid or just one of them
(2-4)
5.2.9 Trigger commands configuration
MXG 1.2 MXP MXS 1.2 STRADA 2019.qxp_Layout 1 15/03/19 11:57 Pagina 41