EVO3 Pro/Pista
User Manual
Release 1.04
www.aim-sportline.com
8
2 7
2.2.3 – Sampling the RPM from the coil: RPM low voltage input
To sample RPM signal from the coil on a low voltage RPM input (from 150 to 400V)
connect pin 13 of 37 pins Deutsch connector (white cable) to the ECU coil input.
2 4
2.2.4 – Sampling the RPM from the spark plug
To sample the RPM from the spark plug an AIM ARP-05 adaptor is needed (part number
X10ADRPM000
) to be installed as shown here below.
Installation steps are:
•
connect
RPM
clip
to the spark plug;
•
connect the black cable labelled
GND
to pin
GND
of the logger;
•
connect the red cable labelled “+12V” to the positive pole (+) of the vehicle battery:
battery voltage has to be
12V
;
•
connect the blu cable labelled “
RPM
” to
EVO3 Pro/Pista
RPM (8-15V) input.
The image here below shows a drawing of RPM adapter – top view.
1 4
2.3 – The lap channel
To sample the lap time connect the infrared receiver included in the kit:
•
to cable labelled “Lap” ending with a 4 pins Binder 712 female connector of 37 pins
Deutsch connector wiring of
EVO3 Pro
;
•
to 4 pins Binder 712 female connector placed right on the front of
EVO3 Pista
and
highlighted in the image here below.