background image

 

 

 

XII. Common troubleshooting 

Failure 

Cause analysis 

Method 

Dehumidifier 

cannot work 

1. Power cut 

2.  Power  switch  is  not 

energized 

3. 

Power 

cord 

is 

not 

connected 

4. Fuse is melted 

1. Recover the power 

2. Energize the power 

 

3. Connect the power cord 

4. Replace the fuse 

Dehumidification 

is not ideal 

1.  Dust  accumulated  in  air 

purification filter mesh 

2.  Object  blocking  air  inlet 

and outlet 

3.  The  door  or  window  is 

open 

4. Refrigerant is leaking 

1. Clear the filter mesh 

 

2.  Remove  the  blocking 

object 

3.    Close  the  door  and 

window 

4. Contact with distributor or 

manufacturer for repair 

Water leak 

1. The machine in inclined 

2. Water pipe is blocked 

1. Level the machine 

 

2.  Remove  the  blocking 

object 

Abnormal noise 

1. The machine is not placed 

solidly 

2. The filter mesh is blocked 

1. Place the machine firmly 

2. Clear the filter mesh 

 

a. Where the above troubles cannot be fixed and repair is needed, please 

contact supplier or distributor. Do not disassemble without authorization. 

b. When the dehumidifier is in operation or stops, voice of circulating of 

refrigerating can be heard. Such phenomenon is normal. 

c. It is normal for the air outlet to drain hot air. 

 

 

 

 

Содержание AD-1500B

Страница 1: ......

Страница 2: ......

Страница 3: ...sed and narrow room Please keep this manual safely Note We advice that any repair should be carried out by professionals II Introduction to Product Dehumidifier is able to reduce air humidity of the space leaving people to live work and store goods in comfortable environment Dehumidifier of our company possesses such advantages of nice appearance compact structure and easy operation It is widely a...

Страница 4: ...y to decrease the set humidity Buzzer buzzes once for each pressing and the set humidity decreases by 1 RH Pressthis button todecrease the presettingtime each pressing and the time d by 1 hour 1 Display range for humidity is 5 98 2 Auto detection of temperature humidity failure a When the system detects that temperature sensor exceeds the limited range the system enters mode of temperature sensor ...

Страница 5: ...ration it will operate the mode of preset stop time The setting hours range is 0 24hours e Press Time button for 10s it display F1 it s humidity correction Press Time button for successively twice it displays F2 it s defrost interval time default 30 minutes Press Time button for successively three times Is displays F3 it s defrost time default 8 minutes Press Time button for successively four time...

Страница 6: ...is any possibility that temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock accidents Please place the machine in firm places If the machine falls down the water in water tank may leak out and damages stuff around and results in creepage and cause fire or ele...

Страница 7: ...5 Otherwise fire or electric shock accident may be caused VIII Electrical wiring diagram IX Unit Dimension ...

Страница 8: ...ication filter mesh may impair its effect or even cause failure Please clear regularly for at least once a month If there is much dust in the environment it must be cleared once a week or once a day Pull does the front panel clear the filter mesh Tap the filter mesh slightly or eliminate the dust by vacuum cleaner or place the mesh in warm water 40oC and addappropriate neutral scour and brush and ...

Страница 9: ...ve the blocking object 3 Close the door and window 4 Contact with distributor or manufacturer for repair Water leak 1 The machine in inclined 2 Water pipe is blocked 1 Level the machine 2 Remove the blocking object Abnormal noise 1 The machine is not placed solidly 2 The filter mesh is blocked 1 Place the machine firmly 2 Clear the filter mesh a Where the above troubles cannot be fixed and repair ...

Страница 10: ...capacity 30oC 80 138 L Day Rated input power 1450 W Air Circulation 1300 m3 h Compressor Aikyo Refrigerant Charge R410A 930g Suction pressure 2 5 MPa Discharge pressure 4 0 MPa Weight 52 kg Unit size 480 415 1065 mm The above parameters are subject to change without serving notice ...

Страница 11: ...amage caused by transportation or handling Customer replaces disassembles and changes machine number without authorization 3 Damage caused by such natural disaster as lightning strike water disaster and Fire 4 Damage caused by use of power with abnormal voltage or power supplied by non power supplying department 5 Where the warranty card is lost reproduced or there is no invoice or no voucher of p...

Страница 12: ......

Отзывы: