background image

 

X. Operation Notices 

1. When moving the machine. do not incline the machine for over  45°  to avoid 

damaging the compressor. 

2. Temperature for operation of this machine is 5-38oC 

3. When it is operating, the compressor gives off heat when it works, and 

ambient temperature may raise by 1-3oC . Such phenomenon is normal and is safe to 
use. When ambient temperature is below 10°C and absolute humidity is relatively 
low, there is no need to use dehumidifier. 

 4.The air inlet and outlet must be away from the wall for at least 10 cm in order 

not to impair the dehumidification  effect. 

5.  Working  environment  shall  be  as  airproof  as  possible  to  maximize 

dehumidification effect. 

6.  Dust  on  the  air  purification  filter  mesh  may  impair  its  effect  or  even  cause 

failure. Please clear  regularly  for  at least once  a month.  If there is much  dust  in  the 
environment, it must be cleared once a week or once a day. Pull does the front panel, 
clear  the  filter  mesh.  Tap  the  filter  mesh  slightly  or  eliminate  the  dust  by  vacuum 
cleaner or place the mesh in warm water (<40oC   and add appropriate neutral scour) 
and brush and then wash with clear water and dry it. 

Direct sunlight or baking shall be avoided to prevent deformation. 

 

XI. Instruction on Code Failure 

This dehumidifier is able to automatically judge failure. If there is any lailure, 
there will be failure code displayed on the humidity display window. 

Failure display 

Problem 

E1 

Temperature defrost sensor failure 

E2, E3 

Ambient humidity/Temp sensor failure, if failure of humidity, it 
displays E2; if failure of temp, it display E3 

E8 

Compressor protection 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание AD-1500B

Страница 1: ......

Страница 2: ......

Страница 3: ...sed and narrow room Please keep this manual safely Note We advice that any repair should be carried out by professionals II Introduction to Product Dehumidifier is able to reduce air humidity of the space leaving people to live work and store goods in comfortable environment Dehumidifier of our company possesses such advantages of nice appearance compact structure and easy operation It is widely a...

Страница 4: ...y to decrease the set humidity Buzzer buzzes once for each pressing and the set humidity decreases by 1 RH Pressthis button todecrease the presettingtime each pressing and the time d by 1 hour 1 Display range for humidity is 5 98 2 Auto detection of temperature humidity failure a When the system detects that temperature sensor exceeds the limited range the system enters mode of temperature sensor ...

Страница 5: ...ration it will operate the mode of preset stop time The setting hours range is 0 24hours e Press Time button for 10s it display F1 it s humidity correction Press Time button for successively twice it displays F2 it s defrost interval time default 30 minutes Press Time button for successively three times Is displays F3 it s defrost time default 8 minutes Press Time button for successively four time...

Страница 6: ...is any possibility that temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock accidents Please place the machine in firm places If the machine falls down the water in water tank may leak out and damages stuff around and results in creepage and cause fire or ele...

Страница 7: ...5 Otherwise fire or electric shock accident may be caused VIII Electrical wiring diagram IX Unit Dimension ...

Страница 8: ...ication filter mesh may impair its effect or even cause failure Please clear regularly for at least once a month If there is much dust in the environment it must be cleared once a week or once a day Pull does the front panel clear the filter mesh Tap the filter mesh slightly or eliminate the dust by vacuum cleaner or place the mesh in warm water 40oC and addappropriate neutral scour and brush and ...

Страница 9: ...ve the blocking object 3 Close the door and window 4 Contact with distributor or manufacturer for repair Water leak 1 The machine in inclined 2 Water pipe is blocked 1 Level the machine 2 Remove the blocking object Abnormal noise 1 The machine is not placed solidly 2 The filter mesh is blocked 1 Place the machine firmly 2 Clear the filter mesh a Where the above troubles cannot be fixed and repair ...

Страница 10: ...capacity 30oC 80 138 L Day Rated input power 1450 W Air Circulation 1300 m3 h Compressor Aikyo Refrigerant Charge R410A 930g Suction pressure 2 5 MPa Discharge pressure 4 0 MPa Weight 52 kg Unit size 480 415 1065 mm The above parameters are subject to change without serving notice ...

Страница 11: ...amage caused by transportation or handling Customer replaces disassembles and changes machine number without authorization 3 Damage caused by such natural disaster as lightning strike water disaster and Fire 4 Damage caused by use of power with abnormal voltage or power supplied by non power supplying department 5 Where the warranty card is lost reproduced or there is no invoice or no voucher of p...

Страница 12: ......

Отзывы: