background image

5

If a sealant is to be used, be sure it is a neutral cure type.

Sealants that release acetic acid may harm camera electronics.
If it is necessary to use a PG type conduit, an NPT to PG

conversion kit (HS9384NPT) can be purchased separately.

Use of drip loops is recommended on the
wiring outside of the rear end cap.

5.6.2

Plug Insertion

If no lens control or feed-through wiring will be used,

remove the preinstalled

3

8

-inch liquid-tight fitting from the

small bottom center hole and install the

3

8

-inch NPT plug

provided. Use a

5

16

-inch (or 8 mm) hex wrench to tighten.

Failure to do so will allow water to enter and cause damage

to all electronic parts (see

Figure 4

).

3/8-inch NPT Plug

Figure 4

3

8

-inch NPT Plug Insertion

Liquid Tight Fitting

(Shown Underneath)

CCD C

a

m

era

WAGO

 

C

onne

c

tor

s

(

Af

ter

C

onne

c

ting

W

ire

s,

P

u

s

h

I

nto

C

a

v

it

y

)

P

ower 

C

a

bl

e

Tie

W

ra

p

s

Fu

s

e

H

o

l

der

Tran

sf

or

m

er

5.6.3

Power Connections

The HS9384-5H, and the HS9384-6H housings allow the use

of 24 VAC cameras, regardless of the supply voltage to the

housing. This is achieved through the use of a transformer in

the housing. The transformer's primary supply power will

vary, depending on the model of housing, see

Section 5.1

Model Designation

. In the 115 volt and 230 volt models,

the transformer also supplies 24 VAC power to the integral

window heater/defogger.
Refer to the following model housing sections for your

model’s wiring procedure.
1. Use the

left

liquid-tight fitting of the housing to route the

power wire into the housing (see

Figure 5)

.

Figure 5 Power Connections

3. Pull any excess wire out of the cradle assembly and tighten

the fitting to 8.5 N.m to 9.0 N.m (75 in.lb to 80 in.lb). This

torque rating is approximately 1 to 1

1

2

turns past the point

where the fitting starts to grip the wire. Failure to do so

will allow water to enter and damage all electronic parts.

Use a tie wrap (included) to provide strain relief on the

power cord at the exit point (inside unit).

Be sure to securely tighten all fittings to ensure
a liquid-tight seal. Failure to do so could allow
water to enter the housing and damage the
camera and lens.

M4 Screw

T

er

minal Lug

2. A screw/terminal lug is provided for securing a safety

ground. Attach the terminal lug to the cradle using the

M4 x 10 screw provided (see

Figure 6

).

Figure 6 Securing Ground Wire

5.6.4

HS9384-6H Housings

The HS9384-6H housings can easily be used with either

115 volt or 24 volt cameras.
The internal transformer provides 24 VAC for both the

heater/defogger and 24 volt camera power (see

Figure 5

).

For 115 volt cameras:

1. Installing a 115 volt camera into the HS9384-6H housing

requires inserting both the field supply wires (115 VAC)

and a section of hook-up wire (not included, minimum

20 AWG wire) into the unused side of the Wago

connectiors (provided), then connecting the other end of

the hook-up wire to the camera’s 110 VAC input.

Repeat for pins 1 and 6 (see

Figure 7

).

2. The secondary flying leads (white/black striped) will not

be used in this application and should be taped to

prevent shorting. See wiring diagram

Figure 7

for

clarification and

Figure 5

for power connection

drawings.

115 VAC
Input

Red

24 VAC

To Heater/Defogger

White/

Black

Striped

To Heater/Defogger

Red

No Connection

(Tape)

White/

Black

Striped

6

5

2

1

12

11

8

7

To Camera 115 VAC

Supply
115 VAC

Wago

To Camera 115 VAC

Supply
115 VAC

Wago

Black

White

Figure 7 HS9384-6H Transformer Wired for 115

Volt Camera

Содержание HS9384-2H

Страница 1: ...I N S T A L L A T I O N A N D O P E R A T I N G I N S T R U C T I O N S OUTDOOR CAMERA HOUSINGS HS9384 SERIES...

Страница 2: ...are not like ly to be walked on or pinched by items placed upon or against them paying particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance...

Страница 3: ...een 4 3 mm 0 170 in 11 9 mm 0 470 in Cable Shape Round Conductors 3 conductor version and 2 conductor version Agency Rating UL C S A UL VW 1 Environmental Outdoor rated Temperature Rating 105 C Voltag...

Страница 4: ...ts for wiring of all cameras and lenses 1 4 20 Screws Spacers Seal Cap Seal Gland Dual Male Portion Retention Screw Figure 1 Removing Cradle Assembly 2 Remove the cradle assembly by simultaneously gra...

Страница 5: ...hten the fitting to 8 5 N m to 9 0 N m 75 in lb to 80 in lb This torque rating is approximately 1 to 11 2 turns past the point where the fitting starts to grip the wire Failure to do so will allow wat...

Страница 6: ...arification and Figure 5 for power connection drawings Figure 8 HS9384 6H Transformer Wired for 24 Volt Camera 5 6 5 HS9384 2H Housings These housings are to be connected to 24 VAC only and are design...

Страница 7: ...h the lens wiring to the lens mating connector and connect it to the lens If the mating connector is not available connect directly to the lens cable NOTE See specification on lens cord for correct pl...

Страница 8: ...ing the instructions provided According to the orientation of the housing the cradle assembly may need to be rotated To rotate the cradle assembly while mounted grasp the rear handle and rotate to the...