Aidcall Astra 6000 Скачать руководство пользователя страница 3

Doc

 

No.

 

FM5610

 

issue

 

B

 

Page

 

3

   

 

2.

 

 

IMPORTANT

 

SAFETY

 

INSTRUCTIONS

 

 
 

 

 

 

Read

 

and

 

understand

 

these

 

instructions

 

before

 

use.

 

Keep

 

these

 

instructions

 

for

 

future

 

reference.

 

 

 

 

Take

 

care

 

when

 

working

 

on

 

step

 

ladders

 

during

 

installation

 

or

 

service.

 

 

 

 

Isolate

 

the

 

mains

 

supply

 

before

 

removing

 

the

 

PSU

 

cover.

 

 

Do

 

not

 

disassemble

 

the

 

transmitter/PSU

 

or

 

attempt

 

to

 

repair

 

it

 

yourself.

  

 

No

 

user

 

serviceable

 

parts

 

inside.

 

Refer

 

all

 

servicing

 

to

 

qualified

 

service

 

personnel.

 

 

 

The

 

PSU

 

should

 

only

 

be

 

connected

 

to

 

a

 

220

240VAC

 

50/60Hz

 

mains

 

supply.

 

If

 

you

 

are

 

unsure

 

of

 

the

 

type

 

of

 

power

 

supply

 

consult

 

your

 

local

 

power

 

company.

 

 

Danger

 

of

 

explosion

 

if

 

the

 

PSU

 

rechargeable

 

battery

 

is

 

incorrectly

 

replaced.

 

Use

 

only

 

manufacturer

 

approved

 

battery

 

as

 

identified

 

in

 

section

 

8

 

of

 

this

 

manual.

  

 

Only

 

use

 

manufacturer

 

approved

 

cable

 

during

 

installation.

 

See

 

section

 

6

 

of

 

this

 

manual

 

for

 

details

 

of

 

cable

 

type,

 

recommended

 

colour

 

code

 

and

 

cable

 

length

 

restrictions.

 

 

 

 

This

 

product

 

should

 

be

 

located

 

at

 

least

 

2

 

metres

 

away

 

from

 

any

 

other

 

electronic

 

equipment.

  

Failure

 

to

 

provide

 

this

 

separation

 

may

 

result

 

in

 

reduced

 

radio

 

range.

 

 

Do

 

not

 

locate

 

this

 

product

 

above

 

a

 

radiator

 

or

 

other

 

heat

 

source.

  

 

Do

 

not

 

expose

 

to

 

direct

 

sunlight.

  

 

Do

 

not

 

submerge

 

in

 

water

 

and

 

do

 

not

 

use

 

in

 

damp

 

or

 

humid

 

conditions.

 

 

Do

 

not

 

expose

 

this

 

product

 

to

 

dripping

 

or

 

splashing

 

water.

  

Liquids

 

can

 

cause

 

a

 

failure

 

and/or

 

a

 

fire

 

hazard.

 

 

Clean

 

with

 

a

 

damp

 

cloth

 

and

 

a

 

non

abrasive

 

cleaning

 

product.

 

Polish

 

with

 

a

 

dry

 

duster.

 

DO

 

NOT

 

use

 

a

 

wet

 

cloth.

  

 

 

 

Avoid

 

using

 

harsh,

 

abrasive

 

or

 

corrosive

 

cleaning

 

agents

 

or

 

detergents

 

(e.g.

 

scouring

 

powders,

 

bleaches,

 

polishes,

 

etc.)

 

when

 

cleaning

 

this

 

product.

 

 

 

 

At

 

the

 

end

 

of

 

its

 

life

 

this

 

product

 

should

 

be

 

disposed

 

of

 

and

 

recycled

 

in

 

accordance

 

with

 

the

 

environmental

 

regulations.

 

See

 

the

 

Regulatory

 

Information

 

in

 

section

 

3

 

below.

 

 
 
 
 
 
 
 
 
 
 
 

 

Содержание Astra 6000

Страница 1: ...olicy of continual product improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Aidcall s Techni...

Страница 2: ...The Transmitter requires connection to the PSU and the Pager Port on a Touchsafe Pro Nursecall Panel Staff will then be alerted to a call no matter where they are via their portable Pagers The system...

Страница 3: ...during installation See section 6 of this manual for details of cable type recommended colour code and cable length restrictions This product should be located at least 2 metres away from any other e...

Страница 4: ...e 2006 6 EC has been put in place to ensure the safe disposal and recycling of batteries Return used batteries to your supplier or drop off at your local municipal waste recycling depot NTENTS 4 MAINT...

Страница 5: ...signal is transmitted to the Pagers POWER SUPPLY LED s The GREEN POWER LED should be permanently illuminated when the Mains supply is healthy The RED FAULT LED will illuminate if the 12V output or bat...

Страница 6: ...0mm from the ceiling and at least 2 metres away from any other electronic equipment IMPORTANT AVOID LOCATING THE TRANSMITTER WITHIN 2 METRES OF OTHER ELECTRONIC EQUIPMENT DIRECTLY ABOVE A HEATER IN DI...

Страница 7: ...mains terminals using the colour code in the table alongside Note the plug is fitted with a 240V AC 5A BS1362 fuse The PSU should only be opened during installation and service the lid must be screwe...

Страница 8: ...des shown below Cable Colour PSU Astra Panel Power Red O P N C Black O P N C Data Yellow N C RXD TX Black N C 0V This cable is available from Aidcall by the metre Part No YW1730 NTS E40104 Astra Trans...

Страница 9: ...he ID s in the boxes above Refer to the J25 Pager User Guide Aidcall Doc No FM5615 for more information Refer to the Scope Pager User Guide Aidcall Doc No FM5620 for more information Select which Pane...

Страница 10: ...p Codes you want the Pager to sound from the pull down boxes alongside each call type Note only 3 different beep patterns are available with the Astra option see the Beep Code table below Set the Re P...

Страница 11: ...oltage across the battery leads is between 13 6V DC and 14 2V DC 13 8V nominal If the battery shows any signs of damage swelling or leakage during an annual inspection it should be replaced immediatel...

Страница 12: ...ctronic Overload Protection Input Voltage 90V to 264V AC 50 60Hz Output Voltage Current 13 6V to 14 2V DC 1A Nominal 13 8V Output Ripple 150mV peak to peak LED Indicators Green Mains Supply Healthy an...

Отзывы: