DAC3060
19
7. MALFUNCTIONS
If the stapler won't go off, check
•
The compressed air input and the condition of the safety lever
•
The condition and function of the nail cartridge
The nail has got stuck to the triggering area
•
Remove the machine from the pneumatic network.
•
Pull the stuck nail out with grippers.
The nail has got stuck inside the holder
•
Remove the machine from the pneumatic network.
•
Pull the nail holder back.
•
Remove the stuck nail and close nail holder by pushing it.
NOTE! In order to avoid damages stop using the machine immediately after you
notice a malfunction.
8. MAINTENANCE AND SERVICE
Before performing maintenance procedures remove the appliances from the network and
remove the compressed air from them.
•
Check and maintain the machines and safety equipment regularly.
•
Never use fuel or any other flammable liquids to clean the tools.
•
When difficult malfunctions occur, contact experienced technicians or the dealer
authorized by the importer.
Lubrication
The stapler must be lubricated before use.
•
Remove the machine from the air network.
•
Turn the machine upside down and place 2-5 drops of oil to the air outlet. Only use oil
that is suitable for pneumatic appliances. Use the machine right after lubrication.
•
Remove the excessive oil. Excessive oil damages the O-ring washers.
•
Daily lubrication is not needed if you use an oil distributor.