You are required by ANSI/SIA A92.5 1990 to read and understand YOUR RESPONSIBILITIES
in
the
OPERATORS MANUAL before you use or operate this work platforrn. The Operators
Manual must always be attached to the work platform.
FAILURE TO COMPLY with your REQUIRED RESPONSIBILMES in the use and operation of
the work platform could result in DEATH OR SERIOUS INJURY.
FAILURE TO AVOID THIS HAZARD WILL RESULT IN DEATH OR SERIOUS INJURY!
(HIS MACHINE IS NOT INSULATED. MAINTAIN SAFE CLEARANCES FROM ELECTRICAL
POWER LINES AND APPARATUS. YOU MUST ALLOW FOR PLATFORM SWAY, ROCK, OR
SAG. THIS WORK PLATFORM DOES NOT PROVIDE PROTECTION FROM CONTACT
WITH OR PROXIMITY TO AN ELECTRICALLY CHARGED CONDUCTOR.
VOLTAGL: h
NGE
(PHASE TO PHASE)
o TO 300V
OVER 300V TO 50KV
OVER 50KV TO 200KV
OVER 200KV TO 350KV
OVER 350KV TO 500KV
OVER 500KV TO 750KV
OVER 750KV TO 1000KV
1 \
WARNING
ELECTROCUTION HAZARD
MINIMUM
SAFE
APPROACH DISTANCE
(FEET)
10
15
20
25
35
45
5
(METERS)
AVOID CON
¡TACT
3.05
4.6
6.1
7.62
10.67
13.72