Mode No.4 (Set the decimal point position of instantaneous flow rate display)

 

If the SET/HOLD switch is pressed when Mode No. 3 is lit, the screen will switch to Mode No. 4 and display the 
following. ("

" shows the present setting value.) 

 
 
 
 
 
1.  When the SET/HOLD switch is pressed for 2 seconds, the setting value will blink, showing ready for setting. 
2.  Each time the SET/HOLD switch is pressed, the setting value will change in turn. (Setting value is -1, 0, 1, 2, or 

3.) 

3.  When the SET/HOLD switch is pressed for 2 seconds, the set value will be lit and setting will be completed. 
 
The setting value shows the digit number of the decimal point position of the LCD. The setting value of 0 means that 
the least significant digit of the displayed value is the digit of 10

0

L /min, and the setting value of -1 means that the 

least significant digit of the displayed value is the digit of 10

1

L/min. 

The following shows the relation between setting value and decimal point position. 

 

 
 
 
 
 
 
 

 

Mode No.5 (Set the interval of upgrading the instantaneous flow rate display) 

If the SET/HOLD switch is pressed when Mode No. 4 is lit, the screen will switch to Mode No. 5 and display the 
following. ("

" shows the present setting value.) 

 
 
 
 
1.  When the SET/HOLD switch is pressed for 2 seconds, the setting value will blink (0.5 sec), showing ready for 

setting. 

2.  Each time the SET/HOLD switch is pressed, the setting value will change in turn. (Setting value is 0.5, 1.0, 2.0, 

3.0, 4.0, or 5.0 sec.) (Default is 2 sec). 

3.  When the SET/HOLD switch is pressed for 2 seconds, the set value will be lit and setting will be completed. 
 
When the SET/HOLD switch is pressed in this state, the screen will return to Mode No.1. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 NH / NK: Function to detect battery voltage drop 

When the battery voltage drops, the least significant digit will blink. 
 
 

 NH / NK storage mode 

NH: When the TOTAL/TRIP switch and the L/min switch are pressed simultaneously for 10 seconds or more, the 
storage mode will be activated and [--------] will be indicated on the LCD.   In the storage mode, when the 
TOTAL/TRIP switch and the L/min switch are pressed simultaneously for 2 seconds or more, the mode will return 
to the measurement mode (integrated flow rate display). 
NK: When the SET/HOLD switch is pressed for 10 seconds or more, the storage mode will be activated and 
[--------] will be indicated on the LCD.   In the storage mode, when the SET/HOLD switch is pressed for 2 
seconds or more, the mode will return to the measurement mode. * No need to use the storage mode in normal use. 

 

4.

 

 

Decimal point position (digit number)

 

 

 

Instantaneous flow rate display 

Mode No.4 

Mode No.5 

No decimal point 

Not indicated on the LCD. 

Set the equivalent value. 

- Display the present set value in the light-on state.

Set the EXP value. 

- Display the present set value in the light-on state.

Set the unit of the instantaneous fkow rate display. 

- Display the present set value in the light-on state. 

Set the decimal point position of the instantaneous flow rate display 

- Display the present set value in the light-on state.

Set the upgrade interval of the instantaneous flow rate display. 

- Display the present set value in the light-on state.

(Blink) 

Approx. 2 sec 

Approx. 2 sec

Approx. 2 sec 

Approx. 2 sec

Approx. 2 sec 

Approx. 2 sec 

Approx. 2 sec

Approx. 2 sec 

(Blink) 

(Blink) 

(Blink) 

(Blink) 

 

 

 

 

.

 

     

 

.

 

  

 

 

.

   

 

.

   

 

   

 

 

 

 

 

Approx. 2 sec

Approx. 2 sec

.

 

     

 

.

 

  

 

 

.

   

 

.

   

   

 

Содержание NH***-4 Series

Страница 1: ...ndard specifications are as follows NH005 4 10mL P NH010 4 1L P NH020 4 1L P NH05M 4 10mL P NH10M 4 10mL P Common to NH and NK Connect the wires with the meter correctly in accordance with the connect...

Страница 2: ...splay or CL display is blinking the screen will be switched to the integrated flow rate display In switching the integrated flow rate value will not be reset If pressed simultaneously for 2 to 4 secon...

Страница 3: ...display digit on the right will blink 4 Each time the L min switch is pressed the setting value will change in turn Setting value is 1 0 1 2 3 4 or 5 5 When the value is set with the TOTAL TRIP switc...

Страница 4: ...the third digit of the integrated flow rate display is counted upward a pulse is outputted 3 When the L min switch is pressed for 2 seconds the set value will be lit and setting will be completed Not...

Страница 5: ...equivalent value of pulse constant If the SET HOLD switch is pressed when Mode No 1 is lit the screen will switch to Mode No 2 and display the following shows the present setting value 1 When the SET...

Страница 6: ...sec 3 When the SET HOLD switch is pressed for 2 seconds the set value will be lit and setting will be completed When the SET HOLD switch is pressed in this state the screen will return to Mode No 1 N...

Страница 7: ...tructive act such as a crime 3 Caused by corrosion due to use in a corrosive environment 4 Caused by acts of animals such as a dog cat rat or insect 5 Caused by a factor other than our product 6 Which...

Отзывы: