Chapter 3. 2U30 JBOD Subsystem Configuration Settings
Rack Venus User Manual
3.6.4.4 How to enable/disable the enclosure alarm by your software
Enclosure control element
Byte / Bit
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT
PRDFAIL
DISABLE RST SWAP
Reserved
1
RQST
IDENT
Reserved
2
POWER CYCLE
REQUEST
POWER CYCLE DELAY
3
POWER OFF DURATION
REQUEST
FAILURE
REQUEST
WARNING
The red LED on BMC module is used for the enclosure alarm. When the LED is solid
on, the alarm is enabled by inband SAS. When the alarm is enabled only by BMC, the
LED is blinking. When the alarm is enabled by both of BMC and inband SAS, the LED is
blinking too.
When the LED is off, the alarm is disabled by both of BMC and inband SAS. The
"REQUEST FAILURE" and “REQUEST WARNING” for Enclosure are defined in the bit1,
byte3 and bit0, byte3 of the "Enclosure control element" in the SES specification.
Setting either bit can enable the enclosure alarm. Clearing both bits disables the
enclosure alarm. We use the software package "sg3_utils" on Linux for example, and
have a SAS HBA and a cable to connect your host with the expander.
(A) Show the device for AIC Expander Controller (canister)
$ sg_map -i
/dev/sg2 AIC 12G Rack 2U30 Exp 0c04
(B) Enable the enclosure alarm
$ sg_ses --descriptor=EnclosureElement01 --set=3:1:1 /dev/sg2
or
$ sg_ses --descriptor=EnclosureElement01 --set=3:0:1 /dev/sg2
(C) Disable the enclosure alarm
$ sg_ses --descriptor=EnclosureElement01 --clear=3:1:1 /dev/sg2
and
$ sg_ses --descriptor=EnclosureElement01 --clear=3:0:1 /dev/sg2
Содержание Rack Venus
Страница 1: ...UM_Rack Venus_v1_110619 Rack Venus Server Rack User s Manual...
Страница 6: ...Document Release History Release Date Version Update Content November 2019 1 Release to public...
Страница 39: ...28 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Страница 45: ...34 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Страница 50: ...39 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Страница 129: ...118 Chapter 7 Pavo Serverboard Rack Venus User Manual 7 6 6 Power Power Option Key Power Wake on PME Enable Disable...
Страница 138: ...127 Chapter 7 Pavo Serverboard Rack Venus User Manual Launch KVM...