46
Chapter 3. 2U30 JBOD Subsystem Configuration Settings
Rack Venus User Manual
3.6.4.2 How to turn on/off the power of a drive slot
Array Device Slot control element
Byte / Bit
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT
PRDFAIL
DISABLE RST SWAP
Reserved
1
RQST OK
RQST
RSVD
DEVICE
RQST HOT
SPARE
RQST
CONS
CHECK
RQST
IN CRIT
ARRAY
RQST IN
FAILED
ARRAY
RQST
REBULD/
REMAP
RQST R/R
ABORT
2
RQST
ACTIVE
DO NOT
REMOVE
Reserved
RQST
MISSING
RQST
INSERT
RQST
REMOVE
RQST
IDENT
Reserved
3
Reserved
RQST
FAULT
DEVICE
OFF
ENABLE
BYP A
ENABLE
BYP B
Reserved
The "DEVICE OFF" for a drive slot is defined in the bit4, byte3 of the "Array Device Slot
control element" in the SES specification. Set the bit to turn off a slot power, and vice
versa. We use the software package "sg3_utils" on Linux for example, and have a SAS
HBA and a cable to connect your host with the expander.
(A) Show the device for AIC Expander Controller (canister)
$ sg_map -i
/dev/sg2 AIC 12G Rack 2U30 Exp 0c04
(B) Get the current state of a slot power. The "Device off=0" means the slot power is
on.
$ sg_ses --page=2 /dev/sg2
Element 0 descriptor:
App client bypass B=0, Fault sensed=0, Fault reqstd=0, Device off=0
(C) Get the descriptor of a slot power
$ sg_ses --page=7 /dev/sg2
Element 0 descriptor: Disk001
(D) Turn off a slot power
$ sg_ses --descriptor=Disk001 --set=3:4:1 /dev/sg2
(E) Turn on a slot power
$ sg_ses --descriptor=Disk001 --clear=3:4:1 /dev/sg2
Содержание Rack Venus
Страница 1: ...UM_Rack Venus_v1_110619 Rack Venus Server Rack User s Manual...
Страница 6: ...Document Release History Release Date Version Update Content November 2019 1 Release to public...
Страница 39: ...28 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Страница 45: ...34 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Страница 50: ...39 Chapter 3 2U30 JBOD Subsystem Configuration Settings Rack Venus User Manual...
Страница 129: ...118 Chapter 7 Pavo Serverboard Rack Venus User Manual 7 6 6 Power Power Option Key Power Wake on PME Enable Disable...
Страница 138: ...127 Chapter 7 Pavo Serverboard Rack Venus User Manual Launch KVM...