51
Chapter 4. BMC Configuration Settings
J4078-01 User Manual
REQUEST
POWER OFF
DURATION
The time that power is scheduled to keep off when power is
cycled.
0: (i) No power cycle is scheduled or
(ii) It is scheduled to be kept off for 10 seconds.
1~60: Power is scheduled to be kept off for the indicated
number of minutes.
63: Power is scheduled to be kept off until manually restored.
FAILURE
REQUESTED
Set by the REQUEST FAILURE on Enclosure Control Element
WARNING
REQUESTED
Set by the REQUEST WARNING on Enclosure Control
Element.