Chapter 4. BMC Configuration Settings
J4078-01 User Manual
Temperature Sensor Element
(A) Temperature Sensor Control Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT PRDFAIL DISABLE
RST
SWAP
Reserved
1
RQST
IDENT
RQST
FAIL
Reserved
2
Reserved
3
Reserved
(B) Temperature Sensor Status Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON STATUS
Reserved PRDFAIL DISABLE
SWAP
ELEMENT STATUS CODE
1
IDENT
FAIL
Reserved
2
TEMPERATURE
3
Reserved
OT
FAILURE
OT
WARNING
UT
FAILURE
UT
WARNING
Field
Value
ELEMENT
STATUS CODE
OK: Everything is Ok
NON-CRITICAL: If either warning limit is exceeded
CRITICAL: If either failure limit is exceeded
FAIL
A warning or failure condition is detected
TEMPERATURE Temperature reading
OT FAILURE
Temperature has exceeded the failure high threshold value
OT WARNING
Temperature has exceeded the warning high threshold value
UT FAILURE
Temperature is below the failure low threshold value
UT WARNING
Temperature is below the warning low threshold value
Содержание J4078-01
Страница 1: ...UM_J4078 01_v1 3_040819 J4078 01 SAS 12Gb s JBOD Series User s Manual ...
Страница 75: ...65 Chapter 4 BMC Configuration Settings J4078 01 User Manual 4 Type in counters to execute counters command ...
Страница 77: ...67 Chapter 4 BMC Configuration Settings J4078 01 User Manual 6 Type in counters to execute counters command ...
Страница 107: ...97 Chapter 4 BMC Configuration Settings J4078 01 User Manual 3 Click Choose File 4 Select and click Open ...
Страница 108: ...98 Chapter 4 BMC Configuration Settings J4078 01 User Manual 5 Click Upload 6 Click Proceed ...
Страница 109: ...99 Chapter 4 BMC Configuration Settings J4078 01 User Manual 7 Wait a few seconds 8 Click Choose File ...
Страница 110: ...100 Chapter 4 BMC Configuration Settings J4078 01 User Manual 9 Choose bin and click Upload 10 Click Proceed ...