3.6.5.3 How to power off/on all disk drives on a disk backplane manually
Power Supply control element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT
PRDFAIL DISABLE RST SWAP
Reserved
1
RQST
IDENT
Reserved
2
Reserved
3
Reserved RQST FAIL RQST ON
Reserved
The "RQST ON" for Power Supply is defined in the bit5, byte3 of the "Power
Supply control element" in the SES specification. Clear the bit on Power
Supply Element “DiskPowerSupply” to power off all disk drives. Set the bit
on Power Supply Element “DiskPowerSupply” to power on all disk drives.
We use the software package "sg3_utils" on Linux for example, and have
a SAS HBA and a cable to connect your host with the expander.
(A) Show the device for AIC Expander Controller (canister) on a disk
backplane
$ sg_map -i
/dev/sg2 AIC 12G 3U16SAS3swap 0c01
(B) Power off all disk drives on the disk backplane
$ sg_ses --descriptor=DiskPowerSupply --clear=3:5:1 /dev/sg2
(C) Power on all disk drives on the disk backplane
$ sg_ses --descriptor=DiskPowerSupply --set=3:5:1 /dev/sg2
Содержание J3016-01
Страница 1: ...J3016 01 SAS SATA JBOD User s Manual UM_J3016 01_v 4 3_051217...
Страница 3: ...contents Chapter 5 Technical Support 97...
Страница 9: ...2 J3016 01 User s Manual Chapter 1 Product Introduction 1 2 Specifications...
Страница 97: ...Chapter 4 BMC Configuration and Setting J3016 01 User s Manual 90 5 Processing 6 Update successful...
Страница 100: ...J3016 01 User s Manual 93 Chapter 4 BMC Configuration and Setting...