![AIC J3016-01 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/aic/j3016-01/j3016-01_manual_2870789039.webp)
Chapter 3 Sub-System configuration Setup
J3016-01 User's Manual
32
3.5.7 How to configure wide port checker
This feature is applicable for SAS drives instead of SATA drives. If there is
no connection with any active SAS initiator by checking all wide ports,
AIC Expander Controller stops all attached SAS drives to save power
consumption of SAS drives. Otherwise, AIC Expander Controller starts all
attached SAS drives to provide drive access service to any active SAS
initiator.
(A) Get the current state of wide port checker
cmd> check_wide_port
Checking wide port is OFF
(B) Enable checking wide port. The new setting will take effect after
reset.
cmd> check_wide_port on
cmd> reset
(C) Disable checking wide port. The new setting will take effect after
reset.
cmd> check_wide_port off
cmd> reset