J3016-01 User's Manual
41
Chapter 3 Sub-System configuration Setup
3.6.4 Implementation on SES Elements
Only the fields highlighted in green are supported.
3.6.4.1. Power Supply Element
(A) Power Supply Control Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT
PRDFAIL DISABLE RST SWAP
Reserved
1
RQST
IDENT
Reserved
2
Reserved
3
Reserved RQST FAIL RQST ON
Reserved
Field
Value
RQST ON
Please refer to section “SES Element Control Functions” for details.
(B) Power Supply Status Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON STATUS
Reserved PRDFAIL DISABLE
SWAP
ELEMENT STATUS CODE
1
IDENT
Reserved
2
Reserved
DC OVER
VOLTAGE
DC
UNDER
VOLTAGE
DC OVER
CURRENT Reserved
3
HOT
SWAP
FAIL
RQSTED
ON
OFF
OVERTMP
FAIL
TEMP
WARN
AC FAIL DC FAIL
Field
Value
ELEMENT
STATUS CODE
OK: No failure or warning conditions detected
CRITICAL: FAIL bit is set due to one or more failure condition
FAIL
A failure condition is detected
RQSTED ON 1: On
0: Off for Disk Power Supply
OFF
1: Off for Disk Power Supply
0: On
AC FAIL
A failure condition is detected
DC FAIL
A failure condition is detected
Содержание J3016-01
Страница 1: ...J3016 01 SAS SATA JBOD User s Manual UM_J3016 01_v 4 3_051217...
Страница 3: ...contents Chapter 5 Technical Support 97...
Страница 9: ...2 J3016 01 User s Manual Chapter 1 Product Introduction 1 2 Specifications...
Страница 97: ...Chapter 4 BMC Configuration and Setting J3016 01 User s Manual 90 5 Processing 6 Update successful...
Страница 100: ...J3016 01 User s Manual 93 Chapter 4 BMC Configuration and Setting...