Ahuja SSA-1000 Скачать руководство пользователя страница 10

Connecting Three SRX-500 Speakers

The Three SRX-500 speakers (each speaker can handle 
400W of power) should be wired in parallel as shown in 
figure. The resulting impedance of the speaker system is 
2.66 . Thus they should be connected to the 2   tap of 
the amplifier.

High Impedance Speakers or Speakers Using A 

100V Line Matching Transformer

l

Only Driver Units / Horn Speakers / Column Speakers 
with 100V Line Matching Transformers are to be 
connected to COM-70V / 100V Terminal Strip.

l

The Box Speaker / Driver Unit switch must be kept at 
Driver Unit position.

l

When any of the above speakers are connected to the 
COM-70V / 100V Terminal Strip then NO Box speakers 
should be connected to the COM-2   /4  Terminal Strip.

l

The power drawn from the amplifier should not exceed 
1000 Watts.

Connecting Seventy Driver Units with 100V LMT

100 Driver Units with 100V Line Matching Transformer
connected at 10 Watts tap can be operated.

Connecting  a  Combination  of  Driver  Units  and 

Column Speakers with 100V LMT

60  Driver  Units  with  100V  LMT  at  10  Watts  and  80 
Column  Speakers  with  100V  LMT  at  5  Watts  can  be 
connected together. The power drawn from the amplifier 
should not exceed 1000 Watts.

1

20W

15W

10W

5W

2

20W

15W

10W

5W

60

20W

15W

10W

5W

10W

7.5W

5W

1

10W

7.5W

5W

2

10W

7.5W

5W

COM

COM

COM

COM

COM

COM

10

Speaker Connection Guidelines....

Resultant Impedance = (8 Ohm / 3) = 2.66 Ohm

COM

4

COM

70V

100V

1

20W

15W

10W

5W

2

100

COM

20W

15W

10W

5W

COM

20W

15W

10W

5W

COM

COM

70V

100V

COM

70V

100V

80

SSA-10000

+

-

SRX-500

8

+

-

SRX-500

8

+

-

SRX-500

8

Connecting  a  combination  of  Wall  and  Ceiling 

Speakers with 100V LMT

130  Ceiling  Speakers  with  100V  LMT  at  4  Watts  and             
80  Wall  Speakers  with  100V  LMT  at  6  Watts  can  be 
connected together. The power drawn from the amplifier 
should not exceed 1000 Watts.

Use of 70 Volt Line

A loudspeaker / Driver Unit with its LMT adjusted to the 

15W tap, when connected to COM and 100V terminals 
on the Amplifier's Terminal Strip will draw 15W from the 
Amplifier but when the same is connected to COM and 
70V it will only draw half power i.e. 7.5W. A good use of 
70V  line  tap  can  be  made  in  installations  where  large 
number of Speakers / Driver Units are to be installed for 
more even distribution of sound.

Correct Phasing of Loudspeakers

l

When two or more Speakers / Units are installed in the 

same  area  and  are  facing  the  same  direction,  it  is 
essential  that  their  cones  /  diaphragms  act  in  unison. 
Otherwise  the  sound  level  of  one  speaker  will  be 
cancelling  the  sound  level  of  the  other.  To  avoid  any 
mistake, the terminals of Box speakers and the Driver 
Units are marked '+' & '-'. Always connect the COM of the 
Amplifier to '-' of speaker & 2  /4   of the amplifier to the 
'+' of the speakers.

l

In  case  of  LMT’s  the  COM  of  all  the  LMT’s  should  be 

connected  to  the  COM  of  the  red  strip  terminal  of  the 
amplifier  and  the  power  tap  to  100V  line  as  shown  in 
figure.

IMPORTANT

l

l

When 70 / 100 Volt line is being used, no speakers / driver units should be connected to 2  / 4  (Low 

Impedance) Tap.

Loudspeaker / driver unit should be connected to either COM-100V or COM-70V terminals, but never to 

more than one set of terminals.

-

+

11

Speaker Connection Guidelines....

1

2W

1W

4W
COM

2

2W

1W

4W
COM

130

2W

1W

4W
COM

1

3W

1.5W

6W

COM

2

3W

1.5W

6W

COM

80

3W

1.5W

6W

COM

COM

70V

100V

SSA-10000

Содержание SSA-1000

Страница 1: ... turning on the power Following the instructions in this manual will enable you to obtain optimum performance from your new AHUJA PA Amplifier l Please retain this manual for future reference Thank you for purchasing the AHUJA PA Amplifier OPERATION MANUAL OPERATION MANUAL 1000W RMS 1350W Max ...

Страница 2: ...t can be connected is marked on the rear panel of the set Do not connect this set to any power source other than those specified on the rear panel Power Cord Protection Do not cut kink damage or modify the AC power cord supplied with this set Keep the AC power cord away from heaters and harmful chemicals Do not keep any heavy object on the power cord Operation on Generator When operating this set ...

Страница 3: ...scription of Product 4 l Front Panel Controls Features SSA 10000 5 l Rear Panel Controls Features SSA 10000 6 l Interconnections 7 l Speaker Connection Guidelines 9 l Typical Applications 12 l Specifications 15 Table of Contents 3 SSA 10000 ...

Страница 4: ...river Unit s diaphragm from unwanted low frequencies Since Box speakers can reproduce the full spectrum of audio frequencies but Driver Units cannot reproduce very low frequencies the switch should be positioned to the Driver Unit side when Driver Units Horns and Column speakers are connected l Circuit Protector Device in place ofAC fuse DC circuit breaker MCB type have been provided these safegua...

Страница 5: ...n the AC circuit protector trips Rectify the cause and press the 10 MIC 6 Input Jack Socket RESET button for resetting normal operation of 11 MIC 7 AUX 3 Switch the amplifier 12 MIC 7 Input Jack Socket 23 LED Array This indicates the output level of the amplifier 13 MIC 8 AUX 4 Switch 24 MASTER Volume Control 14 MIC 8 Input Jack Socket For adjustment of the overall volume level from 15 BASS Contro...

Страница 6: ...rs combined higher power output 35 SPEAKER Terminal Block 2 ohm and 4 ohm 41 AUX 3 Input Jack Socket For connecting low impedance speakers 42 AUX 4 CD Input RCA Socket 36 LINE Input Jack Socket For connecting a CD DVD players For connecting inputs such as an external Mixer 43 BATTERY Terminal Block to enhance the number of inputs Also line output For connecting four 12V Car Batteries in series of ...

Страница 7: ...ys switch ON the Power amplifier after all other units of the audio system have been switched ON After operation switch it OFF first then the other units l The connection diagrams that follow display the typical types of input sources Mics Keyboard Cassette Player Mixer CD Player etc and speakers Wall Ceiling Box Horn Column which can be connected to the amplifier For correct connections and opera...

Страница 8: ...S WITH 100V LMT CEILING SPEAKERS WITH 100V LMT WALL SPEAKERS WITH 100V LMT CASSETTE RECORDER PA MIXER CASSETTE PLAYER CD PLAYER PLAY PAUSE STOP SKIP SEARCH REPEAT MEMORY TRACK OPERATION INDICATOR PLAY REPEAT PROGRAM OPEN CLOSE COMPACT DIGITAL AUDIO POWER COMPACT DISC PLAYER DIGITAL PROGRAM SPEAKERS MICROPHONES AMX 1412 BOOSTER AMPLIFIER ...

Страница 9: ...series combination as shown in figure Two groups of five speakers each are connected in parallel and then the groups are connected in series The resulting impedance would be 3 2 Thus they should be connected to the 2 tap of the amplifier Connecting Four SAX 300DX Speakers The Four SAX 300DX Speakers each speaker can handle 300W of power should be wired in parallel shown in figure The resulting imp...

Страница 10: ...should be connected to the COM 2 4 Terminal Strip l The power drawn from the amplifier should not exceed 1000 Watts Connecting Seventy Driver Units with 100V LMT 100 Driver Units with 100V Line Matching Transformer connected at 10 Watts tap can be operated Connecting a Combination of Driver Units and Column Speakers with 100V LMT 60 Driver Units with 100V LMT at 10 Watts and 80 Column Speakers wit...

Страница 11: ...talled in the same area and are facing the same direction it is essential that their cones diaphragms act in unison Otherwise the sound level of one speaker will be cancelling the sound level of the other To avoid any mistake the terminals of Box speakers and the Driver Units are marked Always connect the COM of the Amplifier to of speaker 2 4 of the amplifier to the of the speakers l In case of L...

Страница 12: ...ted to either Box type speakers or to speakers using the 100V LMTbut NEVER to both together Speaker system impedance should be matched to the output impedance of the amplifier and thus should be connected to the corresponding tap of the amplifier 5 When connecting box speakers to an amplifier the Box Speaker Driver Unit switch should be set to the Box Speaker side and when connecting driver units ...

Страница 13: ...AMPLIFIER will feed all the five amplifiers creating a 3000W output system 6 Loudspeaker connections to each of the five amplifiers should be done independently Each of the amplifiers can be connected to either Box type speakers or to speakers using the 100V LMTbut NEVER to both together Speaker system impedance should be matched to the output impedance of the amplifier and thus should be connecte...

Страница 14: ... RAIN OR MOISTURE T 8A L 240V 50Hz FUSE 1000VA COM 4 8 COM 70V 100V 36V DC INPUT OUTPUT SPA 5000EM 200 mV 1V CAUTION NO USER SERVICEABLE PARTS INSIDE R E F E R S E RV I C I N G TO Q U A L I F I E D PERSONNEL THIS EQUIPMENT MUST BE EARTHED DISCONNECT POWER SUPPLY CORD BEFORE CHANGING FUSE OR REMOVING COVER TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE T 8A L 240V ...

Страница 15: ...ce 50 to 1k 3 Aux 100mV 50k 1 x Aux 250mV 50k CD Aux 4 Line Input 1V 50k Frequency Response 50 15000Hz 3dB S N Ratio 60dB Tone Controls Switch at Box Speaker Position Bass 8dB at 100Hz Treble 8dB at 10kHz Switch at Driver Unit Position Bass 8dB at 100Hz Treble 8dB at 10kHz Pre amp Output 200mV 600 Line Output 1V 1k Output Taps for 2 4 for direct connections Speaker Matching 70 100V Line for use wi...

Страница 16: ...roduced in any manner or translated without written permission Design and Specifications are subject to change without notice owing to continuous product up gradation Technical specifications are subject to production tolerances We cannot be held responsible for printing errors should they occur AHUJA RADIOS 215 Okhla Industrial Estate New Delhi 110 020 INDIA Tel 91 11 26831549 41612474 Fax 91 11 ...

Отзывы: