| Supplement Elektronic contoller CAREL
AHT Cooling Systems GmbH | en
8 / 16
398051_4_0119
Supplement Elektronic con-
toller CAREL
to the operating instructions
– SNr. 347363 Commercial refrigerating appliance
Model types-overview
Commercial refrigeration appliance
Model
Type
R-290
External
dimensions [mm]
Length x Depth x
Height
Maximum
total weight
unit * [kg]
KINLEY XL
KINLEY
XL 210
B 945N
2102 x 663 x
2330-2457**
450
KINLEY
XL 250
B 946N
2502 x 663 x
2330-2457**
500
**Height depends on installed version/appliance
combination. Permanent position on unit base
selectable.
*Model-specific deviations possible. Exact details can
be found in the freight documentation. These must be
available at the operating company.
Technical specifications are subject to change without
notice.
1
Operating elements and
displays
The operating elements and displays can be located
at the following positions:
Standard position
Optional position
Fig. 1:
Position operating elemnts and displays
1.1
Electronic controller CAREL
Buttons are available as operating elements, with the
following assignments:
Fig. 2:
Operating elements and displays
Operating element
Function
Access programming level
Acknowledge alarm
Setpoint setting
Semi-automatic defrost
Switch the cooling function on
and off
Increase setpoint
Increase bus address
Decrease bus address
Decrease setpoint
Optional function: Switch the
door heating on and off
1
Fig. 3:
Displays
Displays (nr./
symbol)
Meaning displays
1
Current temperature
Compressor/cooling function
active
flashes
Alarm compressor/cooling
function
Internal fan active
Defrost active
Door heating active (optional)
Real time clock active
flashes
Alarm real time clock
flashes
Alarm
Operating element
flashes
Alarm