background image

26 

13.   APPENDIX 

13.1  Technical data  

Measuring inputs : 

9 ALMEMO

®

 sockets, suitable for ALMEMO

®

 flat connectors

 

Measuring channels :  9 primary channels, electr. isol.,  max. 31 additional channels 
 

for double sensors and function channels 

A/D converter :  

Delta - sigma, 24-bit, 2.5 / 10 / 50 / 10 mops,  

 

adjustable 1 to 100 

Sensor voltage supply :  

With  mains  adapter  :  12  V,  0.4  A,  with  rechargeable 

battery : 9 to 11.5 V, 0.2 A 

Outputs : 

                

2 ALMEMO

®

 sockets for all output modules

 

Standard equipment : 

Operation : 

1 key 

Date and time-of-day : 

Real-time clock buffered (lithium battery) 

Memory (option S) :  

512-KB EEPROM (64,000 to 100,000 meas. values) 

Microprocessor :           

M16C62P 

Power supply : 

external 9 to 13 VDC

 

Mains adapter 8590-9 :  

ZB 1212-NAx, 230 VAC to 12 VDC, min. 1 A 

Mains adapter 8690-9A :  

ZB 1212-NAx, 230 VAC to 12 VDC, min. 1.5 A 

Rechargeable battery in the 8690-9A : 8 NiMH cells, AA, 9 to 11.5 V, 1600 mAh 
Current consumption  

without active mode :  

approx. 25 mA 

   Input and output modules :  

Sleep mode : 

approx. 0.05 mA 

Housing :  

8590-9 :

 

Polystyrene, 

 

LxWxH 180x49x137 mm , weight: 490 g

 

 

8690-9A : 

Polystyrene,  LxWxH 218x77x145 mm 

Suitable conditions 

Operating temperature        

-10 to +50 °C   (storage temperature  -20 to +60 °C) 

Ambient relative humidity : 

 10 to 90 % rH  

(non-condensing) 

13.2  Product overview  

 

 

 

Order no.  

Data acquisition module

 

ALMEMO

®

 8590-9 

 

 

9 inputs, maximum 40 channels, 2 outputs, cascadable interface, 
1 key,  real-time clock, in 8 DU housing, mains unit 12 V, 0.6 A  

MA 8590-9 

Data acquisition module ALMEMO

®

 8690-9A 

ditto except 12 DU housing with bus and rechargeable battery pack (8 NiMH cells, 1600 
mAh), 
mains unit 12 V, 2 A 

 

MA 8690-9A 

Options 

S:   integrated 512-KB 

EEPROM

  

OA 8590-S 

Q4: Conversion rate of 400 mops for a measuring point with MMC 

SA 0000-Q4 

R:   Measuring ranges for temperature display of 8 refrigerants  

SB 0000-R 

KL:   Linearization, multi-point calibration, calibration data management   OA 8590-KL 

Accessories  

Memory connector including micro SD card, minimum 128 MB  

ZA 1904-SD 

DC power cable, 10 to 30 VDC, 12 V / 0.25 A, electrically isolated  

ZB 3090-UK 

ALMEMO

®

 data cable with USB interface, electr. isol., max.115.2 kbaud ZA 1919-DKU 

ALMEMO

®

 data cable with V24 interface, electr. isol., max. 115.2 kbaud  ZA 1909-DK5 

ALMEMO

®

 network cable, electrically isolated, maximum 115.2 kbaud   ZA 1999-NK5 

ALMEMO

®

 cable with Ethernet interface, electr. isol., max. 115.2 kbaud   ZA 1945-DK 

ALMEMO

®

 input / output cable for triggering and limit value alarms  

ZA 1000-EGK 

ALMEMO

®

 recording cable, -1.25 to 2.00 V  

ZA 1601-RK 

Содержание ALMEMO 8590-9

Страница 1: ...____________________________ Operating instructions English Data acquisition modules ALMEMO 8590 9 and 8690 9A V1 6 26 01 2022 www ahlborn com...

Страница 2: ...ets A1 A2 A1 USB Interface ZA1919DKU Interface optic fib ZA1909DK5 L RS 422 ZA 5099 NVL NVB Ethernet ZA 1945 DK Bluetooth ZA 1709 BTx Trigger input ZA 1000 ET EK Relay outputs ZA 1000 EGK Analog outpu...

Страница 3: ...ial commissioning 11 6 Power supply 12 6 1 Mains operation 12 6 2 External DC voltage supply 12 6 3 Battery operation 8690 9A only 12 6 4 Sensor supply 13 6 5 Switching ON OFF 13 6 6 Data buffering 13...

Страница 4: ...take the time to carefully read these operating instructions and the appropriate sections in the ALMEMO Manual This is absolutely necessary to avoid oper ating and measuring errors and to prevent dama...

Страница 5: ...the batteries have not yet been charged First of all therefore the batteries should be charged using the mains adapter provided continue charging until the CHARGE lamp goes out Rechargeable batteries...

Страница 6: ...ual Ch 6 Complete list of interface commands with all the printouts Manual Ch 7 The operating instructions you are now reading cover only those features and controls that are specific to this device M...

Страница 7: ...ument and to change sensors without the need for any extra settings Function channels Maximum minimum average values and differences from certain measuring points can be programmed as function channel...

Страница 8: ...e continuously scanned at a rate of 10 mops measuring operations per second If there are a lot of measuring points involved the response time can be short ened by increasing the measuring rate accordi...

Страница 9: ...tely logged using the real time clock with date function or in terms of the pure measuring time For the purposes of starting stopping a measuring operation the start stop date and time of day and or t...

Страница 10: ...easured values and all programming parameters can be output to any peripheral equipment RS232 RS422 USB and Ethernet in terfaces are available via the appropriate interface cables Wireless communi cat...

Страница 11: ...pen file terminal log enter file name Save Start measuring operation by actuating the Start button or pressing the START STOP key see Manual 6 6 Stop measuring operation by actuating the Stop button o...

Страница 12: ...ically isolated from the transducers or if a larger input voltage range 10 to 30 V is required then an electrically isolated supply cable must be used either the ZB 3090 UK or for the ALMEMO 8690 9A b...

Страница 13: ...5 Switching ON OFF To switch the device ON OFF the ON OFF key 2 must be pressed To switch OFF press the ON OFF key and hold down for approx 1 second After the device is switched off the real time clo...

Страница 14: ...cated However ALMEMO sensors can if required provide up to 4 channels with 9 input sockets each so that alto gether 36 channels are available The additional channels can be used in par ticular for hum...

Страница 15: ...ts are electrically isolated from one another by means photo voltaic relays A new feature on this device is the additional separation of the measuring inputs from CPU and power supply Between all inpu...

Страница 16: ...hold down to switch OFF again If the device is on and a cycle has been programmed the same key can be used to start and stop a measuring operation The current operating status is clearly shown by the...

Страница 17: ...1 to different device numbers Example Module address 01 0 1 In network operation consecutive numbers between 01 and 99 should be used this ensures that device 00 is not addressed unnecessarily in the...

Страница 18: ...Offline measurement To perform offline measuring operations i e data logging in the device itself you need either option S with a 500 KB EEPROM in the device or an external memory connector with a mic...

Страница 19: ...t scan and then switches off again 7 The measuring operation can be stopped by twice pressing key 2e Func tion ON and STOP In this way any number of measuring operations can be performed in sleep mode...

Страница 20: ...only the last file can be read No selective data output according to date and time or by number The memory connector with the additional memory card can be connected at socket A2 it is recognized auto...

Страница 21: ...ort points can be programmed to the EEPROM in the ALMEMO connector using the AMR Control software menu Measuring points list Pro gram measuring point Measuring point multi point calibration special li...

Страница 22: ...air or phantoms for thermocouples short circuit AB for PT100 sensors use 100 and check Connect the sensors again one at a time and check successively If a fault persists for any one connection then c...

Страница 23: ...the computer see above Check the wiring for short circuit or crossed wires Are all network distributors supplied with power Network the devices again one at a time and check successively see above If...

Страница 24: ...24 12 DECLARATION OF CONFORMITY...

Страница 25: ...12 Declaration of conformity 25...

Страница 26: ...50 C storage temperature 20 to 60 C Ambient relative humidity 10 to 90 rH non condensing 13 2 Product overview Order no Data acquisition module ALMEMO 8590 9 9 inputs maximum 40 channels 2 outputs ca...

Страница 27: ...s 14 26 Measuring inputs 2 Measuring operations 8 Memory connector 20 Micro SD card 20 multi point calibration 21 networking 17 Offline measurement 18 Online measurement with PC 18 Operating controls...

Страница 28: ...Mess und Regelungstechnik GmbH Eichenfeldstra e 1 83607 Holzkirchen Germany internet http www ahlborn com e mail amr ahlborn com Despite great care incorrect information cannot be ruled out Technical...

Отзывы: