When used together with an AHCON Safety Cage:
If Auto-Start is enabled and the attached tire has a higher pressure than the Auto-Start
threshold value of 1.5 bar (2.0 bar for software versions before 1.26), the Door Open
Safety functionality will deflate the tire to
“Open Gate Safe Pressure (1.0 bar).
When the door is closed the inflation sequence will restart automatically.
End:
The filling and adjustment is completed with a beep and "OK" shown on the display.
The PCI will now display (shifting every 2 sec.) both the preset End pressure (End) and the
actual measured tire pressure (Act.).
When the OK sign is shown it is possible to manually adjust the End-pressure of the tire by
pressing the + / - key. Shortly after the
“new” End-pressure is set, the PCI will commence
with the adjustment (new inflation/deflation sequence).
This will end successfully with a new OK sign and beep.
Remove air-hose form the filled wheel and connect the next one.
Stop:
The filling sequence can always be stopped by pressing the "Stop" button.
This will disrupt the filling sequence.
The wheel will deflated until the wheel air-hose is removed.
The “Stop” button is not used in normal filling procedure. Just remove the wheel air-hose
when the tire “End pressure” is reached and the PCI has signaled the OK sign.
Door Stop:
The PCI 1200 can be equipped with a
“Door Stop Circuit” used together with an AHCON
Inflation cage (optional
– see accessories page 17).
If this is present it is possible to prevent exposing the user to high risks in case of tire
explosion.
If the PCI 1200 is used without an Inflation cage,
there is inserted a “Door Stop Jumper” in
the door stop jack of the PCI 1200
(see item 3 page 7 and 8 and accessories page 17).
Removing this jumper will have the same effect as opening a door of the Inflation cage.
The Inflation sequence will be disrupted and the tire air pressure will be vented from a
connected tire.
The PCI will signal a door stop by the message; “Gate Open”.
Re-insert the jumper, close cage doors and disconnect the tire.
Start a new tire inflation sequence.