Specifications:

 

 
All measurements taken with a line voltage of 120 VAC. 
All voltages are RMS. 
All noise measurements are unweighted. 
 

Tube complement:

 Five total; two 12AX7A/7025 high-mu twin triodes    

   and three 12AU7 medium-mu twin triodes 
 

Input Impedance:

 1 M ohm (passive mode) 

   56 K ohm (active mode) 
 

Output impedance:  

 Normal output = 1K ohm. 

   Balanced output = 600 ohm 
   Crossover outputs = 75 ohm. 
 

Signal to noise ratio: 

-80 db 

 

Power requirement:

 100-120-220-240 VAC/50-60 Hz. 

   Internally selectable.  Refer to a qualified service    
   technician to change voltage selection. 
 

Power consumption:

 (at 120 VAC):  0.75 A, 87.75 W 

 

Rack size:

  2 spaces 

 

Weight:

  17 lbs. 

 

INPUTS: 

 

Two Selectable Inputs:

 

 
There are two inputs on the front panel of the DB 680.  There is an input selector switch 
to the right of the inputs.  You can switch manually between inputs one and two.  The 
center position (labeled F/S) is for footswitching, using the provided footswitch.  This 
feature allows you to keep two basses plugged in, and be able to switch easily and silently 
between the two. 
 

Active/Passive Switch:

 

 
This switch applies to both inputs.  Nine times out of ten you’ll use the passive input.   If 
your bass’s output distorts the input section, switch to the active position.  In the active 
position, a 12db pad in the signal path will remedy the situation. 
 

Содержание DB 680

Страница 1: ...le classic studio gear The DB 680 has two fully parametric EQs not semi parametric for complete tone shaping possibilities a tube driven resonance circuit tube effects loop and variable balanced outpu...

Страница 2: ...tion Power consumption at 120 VAC 0 75 A 87 75 W Rack size 2 spaces Weight 17 lbs INPUTS Two Selectable Inputs There are two inputs on the front panel of the DB 680 There is an input selector switch t...

Страница 3: ...ow bandwidth equalization So why have bandwidth control Because many useful cuts are narrow or relatively narrow For example if you think your bass sound is muddy you might want to decrease or cut 200...

Страница 4: ...the loop The loop circuitry is active only when a plug is inserted in either return jack Master Output This controls the level of the signal going to your power amp Crossover section The crossover se...

Страница 5: ...e the 2 or 4 settings will provide better output levels Our balanced output uses the highest quality Jensen output transformer If you hear any ground noise change the position of the ground lift switc...

Страница 6: ...nd lows are separated and sent to the different outputs This frequency the crossover frequency is set by the characteristics of your speakers and amps but most players set it around 500 Hz F X Loop Th...

Страница 7: ...untouched For example you can pull out some 500 Hz from the midrange and leave the lows and highs intact if you set the bandwidth towards the right the narrow mountain because you are creating a narr...

Страница 8: ...s Contact us via phone fax or email techsupport aguilaramp com with a description of the problem We will then issue to you a return authorization number You are responsible for all shipping charges Yo...

Отзывы: