AgSense Aqua Trac Pro Скачать руководство пользователя страница 31

 

Exclusion of implied warranties – Your sole and exclusive remedy is product repair as 
provided in this Limited Warranty. Any implied warranties, including the implied 
warranties of merchantability or fitness for a particular purpose, are limited to two years 
or the shortest period allowed by law.

 

 

 

 

 

This warranty is extended to the original purchaser and any succeeding owner for the products 
purchased for use within the USA. 
Some states do not allow the exclusion or limitation of incidental or consequential damages. This 
warranty gives you specific legal rights, and you may also have the other rights which vary from 
state to state. To know what your legal rights are, consult your local or state consumer affairs 
office or your state’s Attorney General. 
  

DISCLAIMER:

 The use of Field Commander/Crop Link/Aqua Trac shall not be utilized by 

customer as a substitute for the Customer's personal observation of the manner in which 
Customer's irrigation equipment is functioning.  AgSense specifically advises Customer that this 
product is designed to enhance Customer's ability to control existing irrigation equipment and to 
provide the Customer with additional information about existing irrigation equipment.  Field 
Commander/Crop Link/Aqua Trac relies upon GPS, Satellite and Internet technology which not 
always functions properly, accordingly, AgSense disclaims any and all responsibility for the 
reliability of this technology.  Customer acknowledges that AgSense does not have the ability to 
control the reliability of GPS, Satellite and Internet Technology.  AgSense specifically disclaims 
any and all liability for Customer's failure to personally determine whether or not the irrigation 
equipment that belongs to Customer is functioning properly.  AgSense, its agents, members or 
officers will not be liable for Customer's loss of profits, business interruption, or any other type 
of consequential damages arising because of the failure to Customer's equipment, GPS, Satellite 
or Internet to function properly. 
  

CUSTOMER'S RESPONSIBILITIES:

 Customer agrees to keep the irrigation equipment upon 

which Field Commander/Crop Link/Aqua Trac is installed in good repair and maintenance.  
Customer acknowledges the importance of and agrees to keep all safety devices which came with 
Customer's irrigation equipment in working order.  Customer agrees to keep an end field stop 
and barricades in place to prevent damage to the irrigation equipment in the event that Field 
Commander/Crop Link/Aqua Trac malfunctions.  Customer agrees that Field Commander/Crop 
Link/Aqua Trac cannot solely replace the personal monitoring of the operation of irrigation 
equipment. 
  

REMEDY:

 Customer acknowledges that Field Commander/Crop Link/Aqua Trac’s sole 

obligation and Customer's exclusive remedy in the event of any material and continuing 
nonconformity, defect, or error in the information service shall be to take reasonable corrective 
actions upon discovery of the problem. 

 
 

 

Page 29 

 

 

 

 

Содержание Aqua Trac Pro

Страница 1: ...2015 18 Aqua Trac Pro Wiring Manual Revised January 1 2018...

Страница 2: ...g the EnviroPro Probe Page 12 Connecting the Greenshield Probe Page 13 Connecting the Waterscout SM100 Sensor Page 14 Connecting the AgSense Rain Bucket Page 15 Connecting the AgSense Temperature Sens...

Страница 3: ...act your AgSense Dealer to finish setup and configuration of this unit to read the sensors that you have installed Note 2 The pins marked SENSOR POWER as shown above should have a jumper connecting th...

Страница 4: ...olar panel Find the group of terminals 2 with the group label PWR 1 Connect the Black Wire from the solar panel to the terminal marked GND as shown above 2 Connect the White or Red Wire from the solar...

Страница 5: ...of terminals 3 with the group label WM 1 1 Connect the Red wire from the Watermark sensor to the terminal marked PWR as shown above 2 Connect the Black wire from the Watermark sensor to the terminal m...

Страница 6: ...wire from the Decagon 10HS GS1 sensor to the terminal marked PWR as shown above 2 Connect the Bare wire from the Decagon 10HS GS1 sensor to the terminal marked GND as shown above 3 Connect the Red wi...

Страница 7: ...f terminals 3 with the group label SDI 1 Connect the Blue wire from the AquaCheck probe to the terminal marked SIG as shown 2 Connect the Yellow Green stripe wire from the AquaCheck probe to the termi...

Страница 8: ...the Blue wire from the Sentek probe to the terminal marked SIG as shown above 2 Connect the Yellow wire from the Sentek probe to the terminal marked GND as shown above 3 Connect the Red wire from the...

Страница 9: ...e group of terminals 3 with the group label SDI 1 Connect the Red wire from the Decagon Sensor to the terminal marked SIG as shown above 2 Connect the Bare wire from the Decagon Sensor to the terminal...

Страница 10: ...nals 3 with the group label SDI 1 Connect the White wire from the Sentek probe to the terminal marked SIG as shown above 2 Connect the Green wire from the Sentek probe to the terminal marked GND as sh...

Страница 11: ...abel SDI 1 Connect the Green wire from the CS Sensor to the terminal marked SIG as shown above 2 Connect the Clear Black and Orange wires from the CS Sensor to the terminal marked GND as shown above a...

Страница 12: ...s 3 with the group label SDI 1 Connect the Blue wire from the Sensor to the terminal marked SIG as shown above 2 Connect the White wire from the Sensor to the terminal marked GND as shown above 3 Conn...

Страница 13: ...nals 3 with the group label SDI 1 Connect the Blue wire from the Sensor to the terminal marked SIG as shown above 2 Connect the Black wire from the Sensor to the terminal marked GND as shown above 3 C...

Страница 14: ...als 3 with the group label SDI 1 Connect the Green wire from the Sensor to the terminal marked SIG as shown above 2 Connect the Yellow wire from the Sensor to the terminal marked GND as shown above 3...

Страница 15: ...the Sensor to the terminal marked SIG as shown above 2 Connect the Black wire from the Sensor to the terminal marked GND as shown above 3 Connect the White wire from the Sensor to the terminal marked...

Страница 16: ...se Rain Bucket Find the group of terminals 2 with the group label RAIN 1 Connect the Green wire from the AgSense Rain Bucket to the terminal marked GND as shown above 2 Connect the Red wire from the A...

Страница 17: ...Sense Temp Sensor Find the group of terminals 2 with the group label TEMP 1 Connect the Green wire from the AgSense Temp sensor to the terminal marked GND as shown above 2 Connect the Brown wire from...

Страница 18: ...moisture value just to the right Some Sentek sensors will also have an additional column displaying salinity Below the sensor readings is a display of the soil type in the general area where the prob...

Страница 19: ...sensors Page 13 Watermark 200TS Temperature Sensor Page 14 Tank Monitoring Liquid Level Sensor Also included in this section is a new overview picture of the unit Page 10 showing slight changes to the...

Страница 20: ...our AgSense Dealer to finish setup and configuration of this unit to read the sensors that you have installed Note 2 The pins marked SENSOR POWER as shown above should have a jumper connecting the mid...

Страница 21: ...Jumper Settings Note you cannot mix ETape Watermark Decagon 10HS GS1 5v sensors and 12v Tank Monitor Acclima TDR Sensors only 1 type may be used at a time Page 19...

Страница 22: ...p label 1 1 Connect one Green wire from the Watermark sensor to the terminal marked GND as shown above 2 Connect the other Green wire from the Watermark sensor to the terminal marked SIG as shown abov...

Страница 23: ...termark Temp Sensor 200TS Find the group of terminals 2 with the group label TEMP 1 Connect one Red wire from the 200TS Temp sensor to the terminal marked GND as shown above 2 Connect the second Red w...

Страница 24: ...marked PWR as shown above 2 Connect the Red wire from the ETape Sensor to the terminal marked GND as shown above 3 Connect the White wire from the ETape Sensor to the terminal marked SIG as shown abo...

Страница 25: ...to the terminal marked PWR as shown above 2 Connect the Black wire from the Tank Monitor sensor to the terminal marked GND as shown above 3 Connect the White wire from the Tank Monitor sensor to the...

Страница 26: ...as shown above 5 Connect the Black wire from the Pressure Transducer to the terminal marked GND as shown above 6 Connect the White wire from the Pressure Transducer to the terminal marked SIG as shown...

Страница 27: ...ON Closed Connection 1 Connect one wire from the Pressure Switch or Float Switch to the terminal marked PWR as shown above 2 Connect the second wire from the Pressure Switch or Float Switch to the te...

Страница 28: ...ank Monitor sensor to the terminal marked GND as shown above 3 Connect the Yellow wire from the Tank Monitor sensor to the terminal marked SIG as shown above Notes Green wire not used Repeat steps 1 3...

Страница 29: ...eing used in extremely explosive liquids fuels an explosion proof sensor is available contact your dealer to get information and pricing and availability of this sensor from AgSense How To Configure a...

Страница 30: ...air on any unit that fails due to defect in materials or workmanship AgSense labor and parts would be provided free of charge during the warranty period This does not include dealer labor What is not...

Страница 31: ...onsibility for the reliability of this technology Customer acknowledges that AgSense does not have the ability to control the reliability of GPS Satellite and Internet Technology AgSense specifically...

Страница 32: ...AgSense LLC 259 Dakota Ave S PO Box 53 Huron SD 57350 605 352 8350 www AgSense net...

Отзывы: