SPOUT FITTING INSTRUCTIONS
Ensure that the spout is fitted to the bucket discharge side prior to operation. Haulage
requirements can dictate if this has to be removed for transit.
1.
Push spout shaft fully in to nylon bush located on end of auger shaft at discharge
end.
2.
Spout will turn freely on shaft to enable alignment of yellow markers.
3.
Locate fixing bolts (M10 x 30mm cup head square) x 6 into flange, and ensure
flange edges are flush and level and tighten bolts using washers (on nylock side
only) and nylock nuts. Ensure these are tight.