background image

 
 

Step 1

 : Build a sturdy platform out of hard wood (45-50mm thick) or 

metal to hold the estimated max weight of the livestock being weighed. 

 

 

 

 

Step 2

 : Turn the platform upside down and use the spacers provided 

to drill 2 x holes at each corner of the platform. Space these holes and 
the load cells about 200-300mm from each edge of the platform. 
 
If using steel or aluminum – drill or weld on the (4) mounting brackets 
provided and (8) bolts with washers. 
 

DO NOT WELD THE BRACKETS WITH THE LOAD CELLS 

ATTACHED as they will be destroyed by heat damage 

 
If using a hardwood timber platform – purchase (8) coach bolts (12 x 
90-100mm) to secure the load cells to your platform. 
 

Step 3

 :  The load cells are then bolted onto the platform with the 

provided spacers. Ensure the spacers are fitted between the platform 
and the top of the load cell to give the load cells plenty of room to take 
an accurate reading. 
 
 

 

 

 

Содержание Cattle Scales

Страница 1: ...nsure the wiring is replaced in the same order and configuration 4 If the weight reading is not correct in your initial test stand on the scales and weigh yourself follow the simple instructions in this document to quickly calibrate the scales and get operational Equipment Supplied AgriEid Cattle and Livestock Digital Scales 4 x Load Cells with 3 5m cable to connect load cells to junction box 4 x ...

Страница 2: ...f using steel or aluminum drill or weld on the 4 mounting brackets provided and 8 bolts with washers DO NOT WELD THE BRACKETS WITH THE LOAD CELLS ATTACHED as they will be destroyed by heat damage If using a hardwood timber platform purchase 8 coach bolts 12 x 90 100mm to secure the load cells to your platform Step 3 The load cells are then bolted onto the platform with the provided spacers Ensure ...

Страница 3: ...nnected to the center slot on the left hand side of the junction box cable with a Red rubber seal and marked E below Connect the Digital Weigh Indicator cable to the center slot on left provided as above Connect load cell cables in this colour order Black White Yellow Green Red Load cells are positioned on the platform see below to match the ABCD cell wiring above A and B FATHEREST LOAD CELLS FROM...

Страница 4: ...ation to get the system operational Stand on the platform using your own body weight or the person who may be assisting you To Open the Main Menu press HOLD AND PRINT AT SAME TIME To Navigate Up and Down use Tare and Zero buttons see arrows below buttons in diagram below To Navigate Left and Right use Count and Gross see arrows below buttons in diagram below To Enter use the Print button see diagr...

Страница 5: ...ENTER The indicator will auto countdown from 10 to 0 CAL 10 to CAL 0 Zero calibration is completed when the indicator displays 0 0 STEP 2 Weight Calibration Stand in the centre of the scale platform know your exact weight Select C6 Then Select 1 and then press ENTER print button THEN ENTER THE EXACT WEIGHT ON PLATFORM IE 100 KG THEN PRESS ENTER LET THE COUNTDOWN RUN WHEN CALEND IS DISPLAYED CALIBR...

Страница 6: ...form the more accurate the indicator calibration ie 300 400 kg is recommended as this is the around the average weight of a small to medium sized cow As cows are an average weight of 300 600kg you can set the maximum weight reading on the indicator to 1000 kg and use 400kg to calibrate and check the scales are reading this weight correctly Less weight can be used as mentioned above 10 of max say 1...

Отзывы: