THE SWITCH
The machine has a lockable trigger switch. Squeeze the trigger to start
the machine. To lock the switch on, press the lock button while
holding the trigger switch on.
To release, squeeze the trigger and release.
CAUTION: After the machine has been switched off, the spindle
will continue rotating. Take care that parts of your body do not
come into contact with the rotating parts or set the machine down
while it is still rotating
!
NOTE: This tool has anti-restart function. If the power supply is
interrupted while the switch is locked on, when the power returns,
the tool will not turn back on. In this case, the switch must first be
turned off and then back on again.
HOW TO USE THE TOOL
Effective control of this machine requires
two-handed
operation for maximum protection and resistance to
the start-up and operating torque. Place the work properly and hold the machine firmly
WITH BOTH HANDS
to prevent loss of control, which could cause personal injury. Protect your eyes from injury with safety glasses
or goggles.
FRONT HANDLE
The front handle is adjustable. To adjust, loosen the knob, rotate to the desired angle and retighten.
Always ensure that the knob is tight before operating.
OVERLOAD PROTECTION, OVERHEAT PROTECTION
Overload & Load Warning Lamp
When operating within the normal load range, the load warning lamp
will glow green.
When full load is reached, the load warning lamp will flash red. If full
load is exceeded and sustained for too long, the motor will shut down
and the load warning lamp will glow solid red. In this case, the motor
must be first shut off and then restarted. When this happens, the
motor will very likely be near overheating, so it is also a good idea to
run the motor at no load for a few minutes to cool it before
continuing.
Overheat Thermal Protection
If the temperature of the motor gets too high, the thermal protection will shut the motor down. The switch
must be first shut off and then restarted. When this happens, do not immediately start cutting after restarting
the motor. Always run the machine at no load for a few minutes to return to a normal operating temperature