Product Guide – Specifications & Installation

Agnetix A3 1200

Owner / User Responsibilities

Planning

It is the responsibility of the engineer, contractor, installer, purchaser, owner, and user to design the mechanical electrical and 

plumbing systems, install, maintain, and operate the fixtures in such a manner as to comply with all applicable codes, state and 

local laws, ordinances, and regulations. Consult with the appropriate inspector to ensure compliance.

Agnetix case studies, plan examples, and suggestions are not ready-to-submit plans, and are only intended to educate and inform 

a qualified person to develop the best plan for your facility.

The number and type of fixtures, power requirements, cost and complexity of your plan and facility will depend on your

growth style and lighting requirements.

The end user should consider utility incentives which may offset the cost of Agnetix fixtures.

Consult the Facility Planning Guide for detailed planning instructions. These instructions are not a substitute for qualified

engineering services. 

Create an industrial horticultural lighting plan that identifies and locates all fixtures, plumbing runs, and cable runs. Use this 

Product and Installation Guide and qualified engineering services to determine and produce the proper plan for your facility.

The basic procedure is recommended to produce an appropriate plan:

1. Determine your desired PPFD and lighted area for your chamber.

2. Determine room dimensions and canopy dimensions.

3. Calculate the required number of fixtures (N = PPFD * Area (m²)/ Fixture PPF).

4. Choose the desired row and column spacing and the physical layout of your facility.

5. Layout the fixtures as desired, and check that they fit reasonably well. Adjust the spacing as necessary. Note that higher

efficacy fixtures have larger spacing at equal PPFD.

6. Set fixture height above canopy at half of row spacing or higher, and verify it is acceptable.

7. Calculate total power and verify availability of supply.

a. For a retrofit or with traditional HVAC, assume PFACILITY = 1.5 * PLIGHTS

b. For a full hydronic system, assume PFACILITY = 1.25 * PLIGHTS

c. Systems which operate on a 12hr/12hr flip may use as little as half of this power

8. Your engineering professional should use this information to generate a plan for the rest of the system including:

a. Cooling method (Tower, ground source, etc)

b. HVAC (if used)

c. Electrical system

d. Plumbing system

9. Calculate the total cooling loop load.

a. For retrofit, or traditional HVAC systems PLOOP = 0.5 * PLIGHTS (0.4 for DE fixtures)

b. For a full hydronic system, PLOOP can be estimated as PLOOP = PFACILITY

c. Take into account 12hr/12hr flip

10. Determine the parts list per row. www.agnetix.com website includes examples which may be helpful.

a. Consider appropriate check valves and ball valves sufficient for isolation of plumbing loops.

REMINDER:

 Proper handling and maintenance of the cooling loop is required to maintain fixture performance.

Содержание A3 1200

Страница 1: ...ble for Wet Locations ETL Listed PRODUCT SPECIFICATIONS Power 1200W Efficacy 2 23 µmol J A3 Standard Density 2 45 µmol J A3 DD Double Density Spectrum White 5000K 660nm Red others by request Beam Angle 120º Cooling Twin 1 2 Copper Tubes 1 3gpm tube PHYSICAL Housing Aluminum Extrusion Dimensions 36 x 4 x 5 Tube Length 40 Weight 15 Lbs Mounting Through bolts on Light Spine Bolts not included Lens In...

Страница 2: ... A3 1200 DD contain different LED pattern with twice the LED count Light Spine mounting system 5 0 25 25 3 8 x 7 8 3 7 2 0 2 0 3 33 Nominal 40 Nominal 36 5 5 12 14 0 2 0 Downward USB Port 1 RJ 45 Ethernet Network Port w POE RJ 45 Ethernet Network Port w POE USB Port 2 7 8 Power Cable System Connection LED Module 2 LED Module 1 LED Module 3 RJ 45 Ethernet Network Port w POE 1 2 Copper Tubing Do Not...

Страница 3: ... table to determine the acceptability of the power source Connection to a source in excess of 277V will cause immediate fixture destruction and is not covered by the warranty It is recommended and usually most cost effective to use a step up down transformer if needed and to provide 480Y 277 3P 5W service to operate the fixture at 277V where possible 6 Units per 30A cable 3 units per 15A cable Sta...

Страница 4: ...lity The basic procedure is recommended to produce an appropriate plan 1 Determine your desired PPFD and lighted area for your chamber 2 Determine room dimensions and canopy dimensions 3 Calculate the required number of fixtures N PPFD Area m Fixture PPF 4 Choose the desired row and column spacing and the physical layout of your facility 5 Layout the fixtures as desired and check that they fit rea...

Страница 5: ...tubes may be corrected with the gentle use of a tubing expander Do not remove the protective film from the lenses until commissioning in Step 7 If brackets are specified in your plan attach them to the fixtures while the protective supports are still in place Remove the protective end support and one fixture while a second person supports the second unit The protective end support should be replac...

Страница 6: ... correct room row and column of your facility If directed adjust the user power settings as specified by your plan 6 Inspection Do not operate the fixtures before inspection by a qualified person or inspector as required in your jurisdiction Inspect the system for damage and to ensure proper installation of all components Perform formal inspection as required Pressure test as required 4 Make Cable...

Страница 7: ...zes a UL2237 Multi point Interconnection Power Cable Assemblies for Industrial Machinery PVVA listed power cable system to reduce the time and expense of power wiring The system is composed of Outlets 15A and 30A to be installed by your electrical contractor Cables 15A and 30A Tees 15A and 30A Drop Tees 15A Reducers 30A to 15A At 277V up to 6 fixtures can generally be operated from one 30A cable o...

Страница 8: ...INSTALLING IN WET OR DAMP LOCATIONS ENSURE THAT ALL PORTS NOT IN USE ARE CAPPED ALL CONNECTIONS ARE MADE WITH WATERPROOF CONNECTORS OR BOOTS ALL CONNECTIONS ARE PROPERLY TIGHTENED ATTENTION LE PRODUIT DOIT ÊTRE INSTALLÉ CONFORMÉMENT AU CODE D INSTALLATION APPLICABLE UNE PERSONNE FAMILIALE AVEC LA CONSTRUCTION ET L EXPLOITATION DE PRODUIT ET LES DANGERS IMPLIQUES ATTENTION INSTALLER LE PRODUIT CONF...

Отзывы: