AGM Global Vision
18
2.1.17 THERMAL VIEW OBSERVATION
1. Install the Rattler TC on the weapon with a day scope (refer to part 2.1.15 or
2.1.16). Verify that the Rattler TC is securely mounted.
2. Remove the protective caps.
3. Point the equipment at an object.
4. Activate the Rattler TC. After approximately 4 sec, video of the thermal scene
should appear.
5. If the day scope includes a focusing ring (i.e., parallax adjustment knob),
adjust the focus for a parallax-free image.
6. Turn on the day scope’s reticle illumination and adjust the reticle brightness.
7. Adjust the focus of Rattler TC by turning the focus ring.
8. Using the buttons on the control panel, configure the Rattler TC for your
specific situation. Set palette, brightness, contrast, scene mode and FFC
(Flat Field Correction), to display the best image effect.
For more information on operational setting procedures, see Part 2.2 (Main
Functions).
2.1.18 EYEPIECE REPLACEMENT
The device can be used as a clip-on scope or a handheld observation camera.
You can replace the eyepiece to realize different uses of the device.
1. Rotate the fixing ring (Figure 2-10, A) of clip-on output lens (B) counter
clockwise to remove it.
2. Align the optional monocular eyepiece (C) with the grooves (D) of device, and
rotate the fixing ring of eyepiece (E) clockwise to tighten it.
FIGURE 2-10. EYEPIECE REPLACEMENT
E
B
A
D
C