Aginova Sentinel Next Series Скачать руководство пользователя страница 5

                                                                                                                                                                                                      

Page 5 of 8 

Version 2 

 

 

Press button 

If the Mode Button (3) is pressed once for less than 5s, the sensor will display all live sensor value in 
sequence. Then it will show the min and max of each sensor value since the last reset (using the LO 
and HI symbol)  Pressing the Mode Button (3) again during this sequence resets the Hi and Lo 
values stored on the sensor. 
 

Message 

On: Mean sensor is switch On 
Off:Sensor is switch Off 
OtaP: Sensor is being re-flashed over the air 
rst: sensor was reset using the press button (min and max values were reset) 
ErrX: display the error message (check list below) 
DirE: sensor is going to direct mode (after the button was pressed) 
inFr: sensor is going to Infrastructure mode 
CHAr: Sensor is off but the USB is connected (Lo symbol means not fully charged and HI symbol 
means fully charged) 
COnF: Sensor is reconfigured 
rOll: Sensor is rolling back to previous stable setting 

 

Содержание Sentinel Next Series

Страница 1: ...cable is plugged in to the Micro USB input 4 and connected to a charger the Battery Status LED will have the following behavior Solid Green Battery is fully charged Solid Red Battery is charging If bo...

Страница 2: ...quick green blinks Sensor is powering on 5 quick red blinks Sensor is powering off Blinking red at same time as Battery Status LED 1 Battery is almost 100 depleted Sensor cannot function until battery...

Страница 3: ...securely and completely Use only official Sentinel Next probes from Aginova Below is pictured an example of a probe that is properly connected 6 Internal Wi Fi Antenna The Sentinel Next communicates...

Страница 4: ...o not know which version you have contact Aginova support with the sensor ID and they can inform you whether you have Version 1 or Version 2 The following instructions are applicable to Sentinel Next...

Страница 5: ...the sensor Message On Mean sensor is switch On Off Sensor is switch Off OtaP Sensor is being re flashed over the air rst sensor was reset using the press button min and max values were reset ErrX disp...

Страница 6: ...Unknown Error 6 Verify the following points Make sure that your WiFi Access Point AP can reach the internet Verify that the AP is correctly configured SSID channels DHCP etc You can use another device...

Страница 7: ...des in fulfillment of its warranty obligation A replacement product or part including a user installable part that has been installed in accordance with instructions provided by Aginova assumes the re...

Страница 8: ...Y PRODUCT UNDER THIS WARRANTY OR MAKE A PRODUCT EXCHANGE WITHOUT RISK TO OR LOSS OF PROGRAMS OR DATA OBTAINING WARRANTY SERVICE Please access and review the help resources provided in this documentati...

Отзывы: