Aginova Sentinel Next Series Скачать руководство пользователя страница 3

                                                                                                                                                                                                      

Page 3 of 8 

 
 

4. Micro USB Input  

 

        The Micro USB input is used solely for charging the built in rechargeable battery.  To charge, 
plug the Micro USB connector into the Micro USB Input.  Plug the other end of the micro USB cable 
into a USB charging brick with rated output of 5Vdc and minimum 150mA. 

 

 

The Sentinel Next comes with a pre-installed with a 3.6V 

rechargeable lithium battery.

 

 

 
5. Probe Input 
    

The probe input is keyed so it is only possible to connect the probe in the correct orientation.  

Make sure the sensor probe is connected securely and completely.  Use only official Sentinel Next 
probes from Aginova.  Below is pictured an example of a probe that is properly connected. 
 

 

 

 
6. Internal Wi-Fi Antenna 

         The Sentinel Next communicates via the internal 2.4Ghz antenna and is compatible with 
802.11b/g/n Wi-Fi access points.  The Sentinel Next is not compatible with 802.11ac and cannot 
communicate on the 5Ghz band. 
          When installing, it is best to ensure the front of the Sentinel Next is facing the Wi-Fi access 
point as directly as possible.  It is best to ensure there are as few obstacles between the Sentinel 
Next and the Wi-Fi access point as possible. 
 

 

Do NOT place the sensors inside refrigerators/freezers as 
the radio signal will get almost fully attenuated.  

Содержание Sentinel Next Series

Страница 1: ...cable is plugged in to the Micro USB input 4 and connected to a charger the Battery Status LED will have the following behavior Solid Green Battery is fully charged Solid Red Battery is charging If bo...

Страница 2: ...quick green blinks Sensor is powering on 5 quick red blinks Sensor is powering off Blinking red at same time as Battery Status LED 1 Battery is almost 100 depleted Sensor cannot function until battery...

Страница 3: ...securely and completely Use only official Sentinel Next probes from Aginova Below is pictured an example of a probe that is properly connected 6 Internal Wi Fi Antenna The Sentinel Next communicates...

Страница 4: ...o not know which version you have contact Aginova support with the sensor ID and they can inform you whether you have Version 1 or Version 2 The following instructions are applicable to Sentinel Next...

Страница 5: ...the sensor Message On Mean sensor is switch On Off Sensor is switch Off OtaP Sensor is being re flashed over the air rst sensor was reset using the press button min and max values were reset ErrX disp...

Страница 6: ...Unknown Error 6 Verify the following points Make sure that your WiFi Access Point AP can reach the internet Verify that the AP is correctly configured SSID channels DHCP etc You can use another device...

Страница 7: ...des in fulfillment of its warranty obligation A replacement product or part including a user installable part that has been installed in accordance with instructions provided by Aginova assumes the re...

Страница 8: ...Y PRODUCT UNDER THIS WARRANTY OR MAKE A PRODUCT EXCHANGE WITHOUT RISK TO OR LOSS OF PROGRAMS OR DATA OBTAINING WARRANTY SERVICE Please access and review the help resources provided in this documentati...

Отзывы: